Hydraulic power pack with load sensing variable displacement pump and constant displacement pump
•
Lay the electric cables such that they cannot be accidentally pulled or tripped over. Only pull on the plug
in order to remove the plug from the electric outlet.
•
Always remove the plug from the electric outlet before cleaning.
•
If you do not use a pressure filter for your applications, we recommend purifying the mineral oil before
beginning work. To do this, connect each pump outlet P to port T using a tubing line. The entire flow of
hydraulic oil is pumped through the return filter. The pumps should be operated in this way for at least
15 minutes.
•
When commissioning the complete equipment set for the first time, we recommend checking the
hydraulic oil fill-level frequently because all the tubing lines are initially empty.
•
If the diaphragm accumulator is used, replace the fitted drain hose with the longer drain hose included.
Cut the hose to the correct length.
•
There are two options for connecting the discharge measuring container's return hose. Replace the
plugs with the connecting sleeves and secure the return hose with a hose clamp.
46
© Festo Didactic 8068243