Diagnostic Mode, cont'd.
LED segment will be on.
Individual Segment Identification
1
Ignition fault.
2
Door ajar.
3
DC voltage low.
4
DC voltage high.
5
AC mode selected but not available.
6
AC relay stuck closed.
7
AC heater failed open.
Screen 5. Stored Fault History
Press the MODE button to bring up screen 5.
Diagnostic Screen 6 (Initial View) Diagnostic Screen 6 (Second View) Diagnostic Screen 6 (Third View)
Diagnostic Screen 5 (Initial View)
Screen 5 (Initial view)
Screen 5 also displays stored fault history using lighted LED seg-
ments. Refer to illustration below for fault history definitions of the
individual LED segments. If a fault occurred, its assigned fault
history LED segment will be on.
Diagnostic Screen 5 (Second View)
Flame present
with gas off
Service required
error has occured
Individual Segment Identification
1
Thermistor failure.
2
Flame present with gas off.
3
Not used.
4
Not used.
5
Service required error has occurred.
Diagnostic Screen 7 (Initial View)
6
AC voltage has been high.
7
Not used.
Screen 6. Erasing Fault History
2118, 2118IM, 2118IMD Series
Diagnostic Screen 5 (Second View)
Screen 5 (Second view)
All segments shown as being on
Flame present
with gas off
Service required
error has occured
Thermistor failure
1
2
3
Not used
4
Not used
6
5
AC voltage has been high
7
Not used
Press the MODE button to bring up screen 6.
Screen 6 (Initial view)
Diagnostic Screen 6 (Initial View) Diagnostic Screen 6 (Second View) Diagnostic
Screen 6 (Third view)
Diagnostic Screen 6 (Initial View) Diagnostic Screen 6 (Second View) Diagnost
Screen 6 provides a way to erase fault history from memory. To
erase the fault history:
■ Press and hold the Temperature Set button (approximately five
(5) seconds) until "CL" shows on the screen.
■ Once "CL" is displayed, release the Temperature Set button.
■ Press and hold Temperature Set button (approximately five (5)
Thermistor failure
seconds) until "Er" is displayed again. At this point, the fault his-
1
tory has been cleared on both Screen 4 and Screen 5.
2
3
Not used
4
Not used
5
6
AC voltage has been high
7
Screen 7. Power Board Inputs
Not used
Press the MODE button to bring up screen 7.
Screen 7 (Initial view)
Diagnostic Screen 7 (Initial View)
Screen 7 displays "live" power board inputs using lighted LED
segments. Refer to illustration below for "live" input definitions of
the individual LED segments. If a power board input is active or
"live," its assigned input LED segment will be on.
Individual Segment Identification
Diagnostic Screen 7 (Second View)
Flame is sensed
Not used
26
Screen 6 (Second view)
Screen 6 (Fourth view)
Screen 7 (Second view)
All segments shown as being on
Diagnostic Screen 7 (Second View)
Flame is sensed
Not used
Food compartment light
is off and door is closed
1
2
3
Thermistor is sensing fin temperature
4
Not used
6
5
Not used
7
Not used
Food compartment light
is off and door is closed
1
2
3
Thermistor is sensing fin tem
4
Not used
6
5
Not used
7
Not used
www.norcold.com