1. X
General Information
Before installation, read the following instructions carefully. Each Liberty pump is individually factory tested to insure proper
performance.
Closely following these instructions will eliminate potential operating problems, assuring years of trouble-free
service.
Risk of electric shock.
adjustments.
The electrical connections and wiring for a pump installation should only be made by qualified personnel.
This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of
electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.
DO NOT bypass grounding wires or remove ground prong from attachment plugs.
DO NOT use an extension cord.
This pump requires a separate, properly fused and grounded branch circuit. Make sure the power source is
properly sized for the voltage and amperage requirements of the pump, as noted on the nameplate.
The electrical outlet shall be within the length limitations of the pump power cord, and at least 4 feet above floor
level to minimize possible hazards from flood conditions.
The installation must be in accordance with the National Electric Code, Uniform Plumbing Code, International
Plumbing Code, as well as all applicable local codes and ordinances.
Sump and sewage pumps often handle materials which could cause illness or disease. Wear adequate protective
clothing when working on a used pump or piping.
Never enter a pump basin after it has been used. Sewage and effluent can emit several gases which are
poisonous.
Keep clear of suction and discharge openings. To prevent injury, never insert fingers into pump while it is
plugged in.
DO NOT use this product for flammable or corrosive liquid.
DO NOT use this product in applications where human contact with the pumped fluid is common (such as
swimming pools, fountains, etc.)
NEVER dispose of materials such as paint thinner or other chemicals down drains, as they can chemically attack
and damage pump components, potentially causing product malfunction or failure.
DO NOT run pump dry, this product is intended to be partway submerged when operating.
Do not use these pumps in water over 140 F.
The Uniform Plumbing Code (UPC) states that sewage systems shall have an audio and visual alarm that signals
a malfunction of the system, to reduce the potential for property damage.
A 20 amp breaker is recommended for 115V pumps.
Model
HP
PRG101A(V)
PRG101A(V)-2
PRG101M
PRG101M-2
PRG102A
PRG102A-2
PRG102M
PRG102M-2
Always disconnect the pump from the power source before handling or making
Volts
Phase
1
115
1
1
115
1
1
115
1
1
115
1
1
230
1
1
230
1
1
230
1
1
230
1
©Copyright 2015 Liberty Pumps Inc. All rights reserved
X
Full
FNPT
Load
Discharge
Amps
12
2"
12
2"
12
2"
12
2"
6
2"
6
2"
6
2"
6
2"
Automatic or
Note: Manual models ("M"
Manual*
suffix),
approved pump control device
Automatic
or
panel
operation. Operation of these
Automatic
models will be according to the
control selected.
Manual
the electrical specifications of
Manual
the control selected properly
match
specifications of the pump.
Automatic
Always refer to control panel
instructions
Automatic
installation.
Manual
(V) denotes that a vertical float
Manual
switch option is available.
require
a
separate
for
automatic
Make sure
the
electrical
for
proper
- 2 -