Stainless steel hose clamp.
T of 135° with outlet.
Elbow of 45°.
Wooden ground.
Non flammable floor protection.
Stainless steel flexible tube.
Rigid flexible pole adapter.
Anti blow-back seal.
Minimum 200mm.
It must exceed roof height by 1 metre.
If the tube over 4 m in length, the next larger
size will be used.
When installing a flexible tube for gas outlet, be careful that this is not in contact or close to the circuit board
or combustible material.
RECOMMENDATIONS ON THE CHANNELING OF CONVECTION AIR.
The 2 first meters of the pipe must be done in stainless steel.
Convection air must always travel through insulated pipelines.
The maximum length for all pipes channeling air is of 7 meters. If the user needs longer pipes, he/she must
install an additional ventilation motor (see the diagram detailing the different parts).
Stove models Venecia and Ibiza have Ø116cm supply air duct systems. If the user choses not to channel
convection air through a pipeline, the supply air duct system (
drawing 13). To better access the supply air duct system, we recommend removing the top grid (fastened with 4
screws, one at each corner.
With the Kiev model, it is possible to customize the stove's convection air outlets. On each side of the stove,
there is a rod (
) that, depending on its position, forces the stove to blow hot air out through the front (rod placed
backwards, drawing 14), through the back air duct (rod placed forward, drawing 15) or through both (rod in an
intermediate position, drawing 16). The latter option requires the user to use a clamp (
intermediate position.
VENECIA, IBIZA AND KIEV MODELS.
Drawing 13
32
) can be replaced for direct vertical exits (
) that keeps the rod in its
Drawing 12
) (see