Instructions for Use
Electronic Presetting Counter
E5148C1400
1. Inputs
1.1 Reset Input*
This optocoupler input is wired in parallel with the red
SET key and it sets the counter to zero in the up-mode
(incrementing), to the presetting in the down-mode
(decrementing).
1.2 Count Input*
Optocoupler input damped to 25 Hz for DC or AC voltage.
* Note:
The reset input (pin 6) and the count input (pin 5) are
op tocoupler inputs with a common connection (pin 7)
and must be actuated with the same polarity.
1.3 Keyboard Interlock Input
If this input (pin 2) is connected to 3V DC (pin 1), the
front keys are locked (including the SET key).
2. Output
Relay with potential-free contact programmable as NO or
NC contact (NO = normally open, NC = normally closed).
In the up-mode the relay is active at ≥ the presetting, in
the down-mode at ≤ zero. With automatic repetition the
output signal is a timed signal programmable between
100 msec. and 500 msec. in steps of 100 msec. When
the relay is active, a colon will appear at the bottom left of
the display. The switching frequency of the output relay
must not be higher than 4 Hz.
3. Setting the operating mode and
operational parameters
3.1 When installing the unit for the first time or after a
battery change lasting more than 7 minutes, the counter
is set automatically to the programming mode and the 5
parameters must be selected (see 4.2). The parameters
may also be changed during the operation run.
However, this can be achieved only in the programming
mode. In order to reach this mode the following keys
must be depressed simultaneo usly (for safety reasons):
RESET key, the keys of de cade 5 and 6. On the lower
line of the display the message "INIT" appears together
with a down-coun ter subtracting from 5 to 0 in steps of
seconds. If wi thin this period the depressed keys are
released, the previous operating mode will become
active again. If the keys are released after reaching
zero, the first parameter is activated and displayed.
3.2 Setting the Operational Parameters
The key of the first decade allows the user to select the
requested function within the parameters (e.g. add/
subtract) and the 6th decade-key selects the next
parameter. After the last parameter "dP", the program
jumps to the beginning. To leave this program rou tine
the user must step through all parameters (from the
beginning to the end) with NO CHANGES at all.
MN05401013E
Note:
Whenever this routine is selected the program will jump
to the beginning, the previous parameters will get lost
and the count as well as the preset values are zeroed.
4. Operating the counter
4.1 Setting or resetting
Press the red SET button or apply a pulse to the reset
input to set the counter to zero in the accumulating
mode to presetting in the subtracting mode.
4.2 Preset Mode
Presetting is indicated on the lower row of digits. To set
it, use the 6 presetting buttons assigned to each
decade. The set value will be accepted with the next set
or reset operation. Intent of negative presets is to allow
reset to a negative value.
Caution! Do not change presets with output powered.
4.3 Overflow and underflow
In the accumulating mode the overflow is 999999 to 0;
in the subtracting mode it is 0 to 999999. The output
signal remains unaffected.
4.4 Lo-Bat indicator
When the battery charge is too low, "Lo-bat" appears in
the lower display. This flashes in a two-second rhythm.
When "Lo-bat" is indicated, the batteries should be ex -
changed as soon as possible.
4.5 Changing the batteries
Push the battery cover back and remove the batteries,
making certain that polarity is correct (observe "–"
terminal on PCB).
Note:
Changing the batteries should not take longer than 2
min., otherwise the count and preset values as well as
the parameters will get lost and therefore must be set
again (see 3.).
5. Terminal block
Terminal assignment
Terminal No.
7
common AC/DC-input for terminals
6 and 5
6
AC/DC optocoupler reset-input
5
AC/DC optocoupler count-input
4
relay contact
3
relay contact
2
keyboard interlock-input
1
+3V DC for terminal 2
1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Eaton E5148C1400

  • Página 1 Instructions for Use 4. Operating the counter Electronic Presetting Counter E5148C1400 4.1 Setting or resetting Press the red SET button or apply a pulse to the reset input to set the counter to zero in the accumulating 1.
  • Página 2: Technical Data

    6. Example of connection Manufacturer programmed: Counting mode: Autom. repetition: no Relay contact: NO (normally open) Decimal place: Noise suppression The following measures might become necessary: If the counter output actuates inductive loads such as relays and valves, a freewheeling diode for DC current and an RC element for AC current must be installed.
  • Página 3: Conexiones

    Instrucciónes de manejo parámetro. Después del último parámetro “dP” el programa saltará al principio de la rutina de Contador con preseleccion programación. Esta se abandonará sólo cuando se E5148C1400 haya pasado por el programa, sin haber efectuado cambio alguno. 1. Entradas Nota: Siempre que esta rutina sea seleccionada el programa 1.1 Entrada de reposición*...
  • Página 4: Ejemplo De Conexiones

    Terminales Inmunidad al ruido: A VDE 843, Parte 4, Severidad 3 Nº de Terminal Temperatura ambiente: entrada común AC/DC para los –10 ... +50 °C terminales 6 y 5 Temperatura de almacenamiento: entrada de puesta a “0” – –20 ... +60 °C opto-acoplada AC/DC Peso: entrada de contaje –...
  • Página 5 A chaque accès au mode de programmation tous les paramètres sont réinitialisés, cʼest à dire que les Compteur électronique a présélection anciennes valeurs sont perdues, les valeurs de E5148C1400 comptage et de présélection sont remises à zéro. 4. Mise en service du compteur 1. Entrées 4.1 Repositionnement du comptage...
  • Página 6: Exemple De Raccordement

    6. Exemple de raccordement Mesure dʼantiparasitages Les mesures dʼantiparasitages suivantes peuvent sʼavé-rer necessaires: en cas de commutation de charges in-ductives, celles-ci doivent être antiparasitées; pour du courant continu, par des diodes montées en inverse; pour du courant alternatif, par des cellules RC.
  • Página 7 Programmierung geht verloren und der Zähler stand und der Vorwahlwert werden auf Null gesetzt. Betriebsanleitung Elektronischer Vorwahlzähler 4. Bedienung des Zählers E5148C1400 4.1 Setzen oder Rücksetzen Mit der roten SET-Taste oder einem Impuls auf den 1. Eingänge Rücksetzeingang wird der Zähler bei add. Zählweise auf Null, bei subtr.
  • Página 8: Technische Daten

    Wiederholung: keine Ausgangskontakt: n.o. (Schließer) Dezimalpunkt: keiner Eaton Corporation Electrical Group 1000 Cherrington Parkway Moon Township, PA 15108 United States 877-ETN CARE (877-386-2273) Eaton.com © 2007 Eaton Corporation All Rights Reserved Printed in USA Publication No. MN05401013E/CPG March 2007...

Tabla de contenido