ENGLISH
Page 6
Test and Adjust for Proper Flow
Before installing the cleaner head, test and adjust for proper flow. Keeping the hose submerged, attach the quick
connector to the end of the hose. Click the Flow Gauge onto the connector and turn on the pump.
Verify that the red indicator in the gauge (viewed from the side) is on the Number 3 setting.
If necessary, use the valves in the pool equipment area to adjust the flow so that the red indicator is at the Number
3 setting.
•
For skimmer connections on pools with one (1) skimmer, flow is regulated by the FlowKeeper™ Valve.
The red indicator should be at the Number 3 setting.
•
For skimmer connections on pools with more than one (1) skimmer, leave the valve for the skimmer
connected to the hose open, then slowly close the other skimmer until the Number 3 setting is reached.
•
For dedicated suction line connections, leave the vacuum line open and slowly close the
skimmer line until the flow is at the Number 3 setting.
If flow is in the low range (0-2):
• Check and clean the pool filter and baskets if necessary.
• Verify that valves controlling the suction lines are in the open position.
• Increase the flow setting on the FlowKeeper Valve
If flow is in the high range (4-6):
• If using a dedicated suction line, begin to slowly close the valve until the Number 3 setting is reached.
• Lower the flow setting on the FlowKeeper Valve.
• Open the main drain slightly to further reduce flow.
Turn off the pump. Keeping the hose underwater, remove the Flow Gauge by squeezing the pressure points on
either side of the quick connector.
Zodiac
T5 Duo
Suction-Side Pool Cleaner
®
®
6 5 4 3 2 1 0
|
Owner's Manual