11. CLEANING AND SANITIZING

1. Always keep the appliance clean by using a soft damp cloth.
2. Do not use cleaning agents to clean the stainless steel tanks.
3. If appliance will be turned off for more than two days, drain water from all tanks and filters.
4. If the appliance is turned off for over a one week period, filters should be changed and the
appliance should be sanitized.
1. Cleaning the Bottom Tank
a. Unplug the appliance from the wall outlet (picture 3.1-1).
b. Using a Phillips screwdriver, remove both screws from the back bottom plate (picture 3.1-2).
c. Carefully grab bottom tank handle and slowly pull out towards you; without interfering with
tubes and wires, empty remaining water from bottom tank (picture 3.1-3).
e. Wipe the tank walls with a clean, soft damp cloth.
g. Place the UV lamp back into the tank receptacle and screw UV lamp cover back into place.
h. Carefully replace the bottom tank and back bottom plate.
i. Reset flashing filter light (see "Resetting the flashing filter light," page 9).
3.1-1
Unplug from
wall outlet
2. Sanitization
a. Unplug the appliance from the wall outlet.
b. Using a Phillips screwdriver, remove both screws from the back bottom plate (picture 3.1-1).
c. Carefully grab bottom tank handle and slowly pull out towards you; without interfering with
tubes and wires, empty remaining water from bottom tank (picture 3.1-2).
d.
Prepare sanitizing solution: Mix 5 ounces of hydrogen peroxide with one gallon of water.
Pour solution into bottom storage tank until tank is completely full
e. Carefully replace the bottom tanks.
f. Be sure the heating switch is in the "on" position (picture 1.1-1, "Back").
g. Connect the appliance and wait five minutes for the solution to pump from the lower tank to
the upper tank. Then dispense 500 ml (16 oz.) of hot water (be sure to dispose of this water).
Keep remaining solution in top tank for two hours or more.
h. Drain all tanks and water filters.
3.1-2
Remove the
two screws
in the bottom
back plate
www.AtmosphericWaterSolutions.com
3.1-3
Remove lower
storage tank
Remove bottom
back plate
13