6. REPLACING COIL ASSEMBLIES
1.
Push the Power Switch "Off." Wait for the heater tip to reach room temperature.
To disconnect the Coil assembly from the Soldering Handle assembly press the button on the
2.
Coil assembly and pull it away from the Soldering Handle assembly.
Release button
3.
Remove the heater tip from the handle assembly. DO NOT USE METAL TOOLS (SUCH AS
PLIERS) TO REMOVE HEATER TIPS.
4.
Insert the heater tip into the replacement Coil assembly, PS-CA1/PS-CA2.
5.
Align the key in the rear of the Coil assembly with the Soldering handle and insert the new
Coil assembly (with heater tip) into the Soldering Handle assembly until it clicks into place.

7. TROUBLESHOOTING

a.
Power LED Not ON
Check the power cord
Check to see that you have mains voltage
Check to see if the power switch is in the ON position
b.
Tip Does Not Heat
Is the LED Illuminated?
Is the Hand-Piece Connected to the Power Supply?
Is the Coil Assembly firmly inserted into the Soldering Handle assembly?
Is the Tip Firmly Inserted into the Hand-Piece?
If you cannot resolve the problem after conformation of the above, please contact your local OK
International representative.
4
www.okinternational.com
PS-CA1/PS-CA2
PS-800 Rev. 3/1/2006

8. SPECIFICATIONS

Power Supply
Ambient Operating Temperature
Maximum Enclosure Temperature
Input Line Voltage
Input Line Frequency
Power Consumption
Output Power
Output Frequency
Power Cord (3-wire)
Dimensions (approx.)
Soldering Handle w/ Coil
Tip-to-Ground Potential
Tip-to-Ground Resistance
Idle Temperature Stability
Handle Cord Assembly Length
Connector
Dimensions (approx.)
Overall length (with tip)
Grip diameter
Tip to grip
Tip shaft diameter
Tip length
Workstand
Dimensions
W = 101 mm (3.98"), D = 173 mm (6.81"),

9. WARRANTY

Please visit OK International's products web page (www.okinternational.com) where you will find
available information on systems, tips, accessories, technical notes, and more. You may also
contact your local OK International representative for pricing and availability.
OK International warrants the PS-800 power supply and Handle cord assembly against any
defects in materials or workmanship for one (1) year from the date of purchase by the original
owner. This Warranty excludes normal maintenance and shall not apply to any opened, misused,
abused, altered or damaged items. If the product should become defective within the warranty
period, OK International will repair or replace it free of charge at its sole option. The replacement
item(s) will be shipped, freight prepaid, to the original purchaser. The warranty period will start
from the date of purchase. If the date of purchase cannot be substantiated the date of
manufacture will be used as the start of the warranty period.
www.okinternational.com
10 - 40°C
65°C
90 - 240 VAC
50/60 Hz
50 Watts max.
35 Watts max. at 22°C ambient temperature
470 kHz
1.83 cm 18/3 SJT
W = 70 mm (2.76"), D = 161 mm (6.34"),
H = 100 mm (3.94")
< 2 mV
True RMS, 50-500 Hz
< 2 ohms DC, unit on
± 1.1°C in still air
122 cm – burn proof, ESD safe
3-pin power connector
214 mm (8.43") with standard tips
13 mm (0.51")
58 mm (2.28")
5.5 mm (0.22")
52 mm (2.05") (typical)
H = 76 mm (3.0")
5