Ce Comments; Emc Directive - Fluke 917X Serie Funcionamiento Básico

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 105
Component lifetime can be shortened by continuous high temperature operation.
DO NOT apply any type of voltage to the switch terminals. Applying a voltage to the terminals
may cause damage to the controller.
DO NOT use fluids to clean out the well. Fluids could leak into electronics and damage the
instrument.
DO NOT introduce any foreign material into the probe hole of the insert. Fluids, etc. can leak into
the instrument causing damage.
DO NOT change the values of the calibration constants from the factory set values. The correct
setting of these parameters is important to the safety and proper operation of the calibrator.
DO NOT slam the probe sheath or sleeves into the well. This type of action can cause a shock to
the sensor and affect the calibration.
The instrument and any thermometer probes used with it are sensitive instruments that can be
easily damaged. Always handle these devices with care. DO NOT allow them to be dropped,
struck, stressed, or overheated.
DO NOT operate this instrument in an excessively wet, oily, dusty, or dirty environment. Always
keep the well and inserts clean and clear of foreign material.
The Metrology Well is a precision instrument. Although it has been designed for optimum
durability and trouble free operation, it must be handled with care. Always carry the instrument in
an upright position to prevent the probe sleeves from dropping out. The convenient handle allows
for hand carrying the instrument.
If a mains supply power fluctuation occurs, immediately turn off the instrument. Power bumps
from brown-outs could damage the instrument. Wait until the power has stabilized before re-
energizing the instrument.
The probe and the block may expand at different rates. Allow for probe expansion inside the well
as the block heats. Otherwise, the probe may become stuck in the well.
Most probes have handle temperature limits. Be sure the air temperature above the Metrology
Well does not exceed the probe handle's temperature limit. If the probe handle limits are
exceeded, the probe may be permanently damaged.

CE Comments

EMC Directive

Fluke's Hart Scientific Division equipment has been tested to meet the European Electromagnetic
Compatibility Directive (EMCEMC Directive, 89/336/EEC). The Declaration of Conformity for
your instrument lists the specific standards to which the instrument was tested.
Before You Start
CE Comments
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

9170917191729173

Tabla de contenido