1. GENERAL WARNINGS
- These pumps are recommended for
pumping very dirty and sewage water.
They must be used in compliance with
local laws.
- Before installation and use read the
following instructions carefully. The
manufacturer declines all responsibility
in the event of accident or damage due
to negligence or failure to observe the
instructions described in this booklet
or in conditions that differ from those
indicated on the rating plate. It also
declines all responsibility for damage
caused by improper use of the water
pump.
- When storing, do not pile weights or
other boxes on top.
2. SAFETY
- Before carrying out checks or doing
any maintenance, clear the system by
disconnecting the voltage, unplug the
pump from the socket and then rinse
the pump well with clean water.
- The water pumps comply with the
EEC Directives 73/23/EEC, 98/037/EEC,
89/336/EEC including the latest
amendments.
- Before installing the water pump,
make sure that the power supply mains
is earthed and complies with
regulations.
-They are not suitable for pumping
inflammable liquids or for operating in
places where is danger of explosion.
Avoid contact between the power
supply and the liquid to be pumped.
Do not modify the components of the
water pump.
- The water pump must never be lifted
or transported by its supply cable or
float switch; it must be held by the
appropriate handgrip.
- Keep hands or other object away from
the hole under the pump casing near
the supporting feet.
- Do not use the pump in swimming
pools, garden ponds or similar places
when people are in the water.
3. PERLIMINARY INSPECTION
- Unpack and check that it is in perfect
condition. Also check that the data
on the rating place correspond to the
required data.
- If there is any problem contact the
supplier immediately, specifying the
type of fault.
CAUTION: If there is any doubt about
the safety of the machine, do not use it.
4. CONDITIONS OF USE
- The following conditions must be
observed when using the water pump:
- Maximum fluid temperature: 40ºC.
- Maximum density of the liquid
pumped: 1,1Kg/dm3.
- pH of the liquid: 5 / 9
- Voltage variation allowed: ± 5%
(in the case of single-phase voltage
220/240V and three-phase voltage
EN
3