2.0 TECHNICAL CHARACTERISTICS
2.1 General rules
Install the pump:
On an horizontal reinforcement (ex: stoking tank) or on the pump
Far from an hot source in dry places at maximum temperature of 45°C
In a ventilated place and easily accessible by an operator for
At a suitable height above the chemical up to a maximum height of 1.5
Do not install the pump over the tank in presence of liquids that
2.2 Standard accessories supplied
1 Foot valve / Strainer.
1 Injection fitting / pressure loading valve.
2 meters opaque PE delivery tubing.
2 meters PVC clear suction tubing.
2 meters PVC clear priming tubing
2.3 Electrical characteristics
Power supply: 230 VAC 50/60 HZ
Upon request (all series)
115 Volt AC 50-60 Hz
Only for series HC1
24/12 Volt DC – 24 Volt AC
2.4 Electric connection
CAUTION !!!!!
Verify that the earth system is perfectly functional and complies with the applicable
regulations. Make sure that the highly sensitive differential switch is present (0.03
A). Verify that the rated values of the pump are compatible with those of the mains.
Never install the pump directly in parallel with inductive loads (e.g. motors/solenoid
valves) if necessary, use an isolating relay.
There are 2 protection devices inside the pump: a varistor and a fuse.
Cod. ADSP7000176A Rev.1.7 (21/07/2014)
shelf (optional) so that the pump head stays always in vertical
position +/-15°.
and minimum 0°C.
periodical maintenance.
meters. If for xigency of the plant it's necessary to install the pump
under the level of the chemical, you need to use an injection valve or
an anti siphon valve.
emanate fumes unless it is hermetically closed.
I- Switcher or multi-pole security device
E- Motor or generally inductive
12
P- Metering Pump
R- Relay
charge
A- Supply voltage