Install Indoor Unit; Dimension Drawing Of Indoor Unit Installation; Mounting Plate; Wall-Through Hole - Beko BEVPA 090 Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

8

Install indoor unit

8.1 Dimension drawing of indoor unit installation

Space to the wall
20 cm above

8.2 Mounting plate

1. The wall for installation of the indoor unit shall be hard and firm, so as to prevent vibration.
2. Use the "+" type screw to fasten the peg board, horizontally mount the peg board on the wall, and
ensure the lateral horizontal and longitudinal vertical.
3. Pull the peg board by hand after the installation, to confirm whether it is solid.

8.3 Wall-through hole

1. Make a hole with an electric hammer or a water drill at the predetermined position on the wall for
piping, which shall slant outwardly by 5°-10°.
2. To protect the piping and the cables from being damaged running through the wall, and from the
rodents that may inhabit in the hollow wall, a pipe protecting ring shall be installed and sealed with
putty.
Split type wall mounted air-conditioner / Owner's Manual
Space to the ceiling
15 cm above
200 cm above
Space to the floor
Space to the wall
20 cm above
33 / 220 EN

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido