TECHNICAL DATA
14 Additional datasheet
Outdoor unit
Indoor Unit
Outdoor
Sound Power Level Cooling Nom.
Outdoor
Sound Power Level Heating
Sound Power Level Cooling Nom.
Indoor
Outdoor
Rated Airflow
Indoor
Rated Airflow
Indoor
Rated Airflow
Refrigerant type
GWP
Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to
global warming than a refrigerant with higher GWP, if leaked to the atmosphere.This appliance contains a refrigerant fluid with a
GWP Fixed Text
GWP equal to 2087.5. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global war-
ming would be 2087.5 times higher than 1 kg of C02, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
Capacity control
Cooling function included
Heating function included
Average climate included
Cold season included
Warm season included
Energy label
Pdesign
Cooling
SEER
Annual energy consumption
Energy label
Pdesign
Heating
(Average
SCOP
climate)
Annual energy consumption
EN
Required back up heating cap at design conditions kW
A Condition (35°C - 27/19)
B Condition (30°C - 27/19)
Cooling
C Condition (25°C - 27/19)
D Condition (20°C - 27/19)
- 22 -
outdoor 7(6) /
indoor 20 (max 15)
Cooling
Heating
Cooling
Heating
Pdc
EERd
Pdc
EERd
Pdc
EERd
Pdc
EERd
17-025 NWO
17-035 NWO
17-025 NWI
17-035 NWI
dB(A)
63
dB(A)
N.A.*
54
dB(A)
m³/min
1800
m³/min
1800
m³/min
600
m³/min
600
R410A
2087.5
Variable
Yes
Yes
Yes
No
No
Yes
kW
2,7
5,6
kWh
168
Yes
kW
2,8
3,8
kWh
1032
0,3
kW
2,7
3,00
kW
1,99
4,20
kW
1,28
7,00
kW
0,57
9,40
17-050 NWO
17-050 NWI
63
63
N.A.*
N.A.*
54
58
1800
3200
1800
3200
580
850
580
850
R410A
R410A
2087.5
2087.5
Variable
Variable
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
Yes
Yes
3,5
5,2
6,1
5,6
201
325
Yes
Yes
3,2
4,5
4
3,8
1120
1658
0,6
1
3,5
5,2
2,72
3,1
2,58
3,9
4,5
4,6
1,66
2,5
7,8
6,6
0,74
2,2
10,5
9,1
SDH17-NW-I_EN - 01/15 - Saunier Duval
17-065 NWO
17-065 NWI
68
N.A.*
63
4000
4000
1000
1000
R410A
2087.5
Variable
Yes
Yes
Yes
No
No
Yes
6,4
5,1
439
Yes
5,8
3,8
2137
1,4
6,2
2,8
4,5
4,3
3
5,8
2,1
7,1