Dip switches
AUTOMATIC
1
CLOSING
2
2 / 4 STROKE
MAN
3
PRESENT
Note: in the Man Present mode, the PP input (n° 13) is disabled, as is the radio receiver.
4
5
ENCODER
PRE-FLASHING
6
FOTOTEST
CLOSE
7
AFTER
PHOTOCELL
NO
8
REVERSE
OPENING
9
PHOTOCELLS
OPERATION
10
BREAKING
Note: the breaking system activates whenever the motor must stop (FCC - FCA - STOP – change
of direction) and reduces the inertia accumulated by the gear motor during movement.
Clock function:
A timer can be connected to the open-close pushbutton in order to keep the gate open at certain times
during the day, after which it reverts to automatic closing.
6. DIAGNOSTICS LED
DL1
STOP button green LED signal
DL2
PEDESTRIAN button red LED signal
DL3
STEP BY STEP button red LED signal
DL4
OPEN button red LED signal
DL5
CLOSE button red LED signal
DL6
SENSITIVE EDGE green LED signal
DL7
PHOTOCELL green LED signal
DL8
CLOSE LIMIT SWITCH green LED signal
DL9
OPEN LIMIT SWITCH green LED signal
after opening, the gate automatically closes when the delay set on the
On
T.C.A. trimmer expires;
Off
a command is required to close the gate;
with automatic closing enabled, a sequence of open/close commands
On
causes the gate to OPEN-CLOSE-OPEN-CLOSE etc.;
in the same conditions, the same command sequence causes the gate to
Off
OPEN-STOP-CLOSE-STOP-OPEN-STOP (step-by-step) (see also dip switch 9);
Man Present; the automation system will continue to open or close as
On
long as the OPEN or CLOSE buttons are held down. The gear motor will
stop when the button is released;
normal (or pulse); when the OPEN, CLOSE or the PP button is pushed, the
Off
automatic system performs a complete opening or closing manoeuvre;
Leave dip-switch 4 in Off;
On
encoder disabled (obligatory if the motor is not fitted with an encoder);
Off
encoder enabled (only for motors with encoder);
On
pre-flashing and "photocell test" function enabled;
Off
pre-flashing and "photocell test" function disabled;
after the photocell contact triggers (input 16 - 18), the automation system
On
closes after 5 seconds;
Off
function disabled;
On
the gate works as set by dip switch 2
Off
the gate ignores the close command during the opening cycle;
during opening, the photocell cuts in to stop the gate until the obstacle
On
is removed. During closing, it stops the gate and then totally reopens it.
during opening, the photocell does not trigger while during closing, it be-
Off
haves as if the dip switch were on;
On
breaking enabled;
Off
breaking disabled;
13