Countertop Requirements

9
WARNING
To reduce the risk of ignition of surrounding
combustible materials, install at least 6" (150 mm)
from both sidewalls and at least 2" (51 mm) from
the rear wall.
The countertop must be level and horizontal. The
stability of the countertop must be maintained after the
cut-out has been made.

Technical Data

Total connected load electric: 0.8 VA
Gas
Pressure
A-burner full burn
A-burner low burn
B-burner full burn
B-burner low burn
Total connected load
Total consumption
8
Natural Gas
LPG (Propane)
6" water
10" water
column
column (2.5 kPa)
(1.5 kPa)
94
74
49
36
128
87
58
42
16,000 BTU/h
16,000 BTU/h
(4.7 kW)
(4.7 kW)
0.45 m³/h
340 g/h

Installation Procedure

Prepare Installation Space

Create the cut-out in the countertop for one or several
Vario appliances according to the installation diagram.
The angle of of the cut surface to the countertop must
be 90°.
After creating cut-out, remove shavings. Seal cut
surfaces in a heat-resistant manner.
Some solid surface countertops require special
installations. For example, heat reflective tape and
rounded corners may be necessary. Contact the
countertop manufacturer for instructions specific to
your countertop.
Observe minimum distance between appliance
underside and furniture parts of
When installing multiple Vario appliances:
account space requirement for VV 200 connection strip
between the appliances. Appliances can also be
installed in individual cut-outs, bearing in mind a
minimum distance between the appliances of 1
(40 mm).

Install Appliance

9
WARNING
Before you plug in an electrical cord or turn on
power supply, make sure all controls are in the
OFF position.
1
Make a mark exactly in the center of the cut-out.
Fasten the mounting rails to the front and rear edge
of the cut-out. The leading edges of the mounting
rails must lie upon the countertop. The center
marking of the mounting rails must correspond
precisely with the center marking of the cut-out.
I n s t a l la t i o n P r o c e d u r e
P r e p a r e I n s t a l la t i o n S p a c e
3
/
" (10 mm).
8
Take into
/
"
9
16

Publicidad