Manual Operations by Program

This type of manual watering is also known as "Semi-automatic" operation.
When a program is started manually, it runs through the watering cycle as if it
had been started automatically. A single program can be selected and started or
multiple programs can be selected to run in sequence.
• Single Program Operation
1. Set the Program Switch to select program A, B, C, or D.
2. Turn the Function Dial to the Manual Programs
program letter and MAN will be displayed.
3. Press the
button. The program identification letter will begin flashing
and the Water On
4. Turn the Function Dial to the RUN
will be displayed. The operating station number and the Water On
be flashing. The stations will operate one at a time (for their set run time) in
numeric sequence. The automatic mode will resume when the manual opera-
tion is finished.
Note: To turn off an active station and start the next station in sequence,
press the
button. Manual operation will be terminated when the last station
number displayed has completed it's run time or has been skipped.
To terminate operation, turn the Function Dial to the OFF
Wait for display to stop flashing, then return the dial to the RUN
• Multiple Program Operation
1. Set the Program Switch to select program A, B, C, or D.
2. Turn the Function Dial to the Manual Programs
program letter and MAN will be displayed.
3. Press the
button to start the program watering cycle. The program
identification letter will begin flashing and Water On
4. Set the Program Switch to select another program A, B, C, or D.
5. Press the
button. The program letter will begin flashing and the previous pro-
gram letter will remain on. The selected program will be placed in sequence.
6. Repeat steps 4 and 5 to sequence additional programs.
7. Turn the Function Dial to the RUN
ating will be displayed. The operating station number and the Water On icon
will be flashing. When the program has finished, the next program in sequence
will start. The automatic mode will resume when the manual operation is finished.
Note: To manually turn off an active station and start the next station in
sequence, press the
number displayed has completed it's run time or has been skipped.
To terminate operation, turn the Function Dial to the OFF
Wait for the display to stop flashing, then return the dial to the RUN
icon will be displayed.
position. The program letter currently oper-
button. The program will end when the last station
position. The selected
position. The selected station numbers
position. The selected
icon will
position.
position.
icon will be displayed.
position.
position.
13