Valve Test Function

This feature allows you to quickly step through the operation of each station for
initial installation check, periodic maintenance, spring start-up etc.
The preset time for each station is two minutes but can be quickly adjusted from
30 seconds to 10 minutes.
Note: Only stations with a run time (assigned to any program) will be included in
the test operation.
1. Turn the Function Dial to the Valve Test
with an assigned run time in any program will be displayed. The display will
show 2 M (2 minutes) of run time per station.
2. To change the valve test duration, press the
time from 30 seconds to 10 minutes.
3. Press the
button. The first station in sequence will turn on. The operating
station number and Water On
4. Turn the Function Dial to the RUN
at a time in numeric sequence. The automatic mode will resume when the
valve test operation is finished.
Note: To turn off an active station and start the next station in sequence,
press the
button. Review operation will be terminated when the last station
number displayed has completed it's run time or has been skipped.
To terminate operation, turn the Function Dial to OFF
stop flashing, then turn the dial to the RUN
Program Review
The Program Review feature provides a convenient method of reviewing all
user-defined programming information.
Program elements will be displayed as follows:
• Cumulative run time of all assigned stations (adjusted for Water Budget and
Well Recovery delay time).
• Station run times in each module bay.
• Program start times
• All flow settings (when flow sensing option is used).
1. Turn the Function Dial to the Review
2. Set the Program Switch to select the program to be reviewed.
3. Press the
button to index through the program information.
4. When finished, turn the Function Dial to the RUN
icon will begin flashing.
Function
position. All station numbers
or
buttons to select a run
position. The stations will operate one
position.
position.
position.
. Wait for display to