25

Programming the key button

The kit has 2 relays (relay 1 and relay 2) for each connected external
unit.
Their operation can be programmed both during a call and in standby.
With each button programmed for the relay command, it is possible to
simultaneously activate up to 2 relays*.
In the case of calls, one of the relays that can be activated must be
the relay of the calling door.
• KEY BUTTON
1. Enter the Installer menu (See point 19).
2. Select the Buttons Programming menu using the
and press the
button to enter.
EN
3. Press the
button to enter the Program key button menu.
BUTTONS PROGRAMMING MENU
4. Select the mode whose function you want to modify using the
buttons and press the
Configuration during call
Configuration at rest time
5. Select the editable fi elds using the
value using the
,
Activate:
Calling door, relay:
Door 1 ,relay 2
Left
6. Press the
button to exit and save the changes.
40
INSTALLER MENU
Buttons Programming
1
2
Program key button
button to confi rm.
SET RELAY
,
buttons and change the
or
buttons.
RELAY DURING CALL
2
Activate:
Right
26

Programming the Privacy / Doctor button

The Privacy function silences the ringtone of calls from an
external unit or intercom unit.
The Doctor function enables automatic activation of the lock-
release (relay 1) in response to an external unit call.
The Doctor + Privacy function, as well as disabling the external
unit ringtone in the same way as the Privacy function, also enables
automatic activation of the lock-release (relay 1) in response to an
external unit call.
1. Enter the Installer menu (See point 19).
2. Select the Buttons Programming menu using the
,
buttons
and press the
3. Select the Confi gure Privacy/Doctor menu using the
buttons and press the
,
4. Select the function that you want to assign to the button using the
,
buttons and press the
5. Press the
button to enter.
INSTALLER MENU
Buttons Programming
button to enter.
BUTTONS PROGRAMMING MENU
1
2
Privacy/DoctorSettings
button to confi rm.
CONFIGURE PRIVACY/DOCTOR
Doctor mode
Privacy
Doctor mode + privacy
button to exit and save the changes.
,