RECEPTACLES
120 Volt AC, 20 Amp, Duplex
Receptacle
This is a 120 Volt AC outlet, consisting of a pair of
receptacles protected against overload by a 20 Amp
push-to-reset circuit breaker.
120 Volt AC, 30 Amp Receptacle
Use a NEMA L5-30 plug with this receptacle. Connect
a 3-wire cord set rated for 125 Volts AC at 30 Amps
(or greater) to the plug.
Cord Set
NEMA L5-30
Use each receptacle to power 120 Volt AC, single
phase, 60 Hz electrical loads requiring up to a
combined 2400 watts (2.4 kW) or 20 Amps of current.
Use only high quality, well-insulated,
3-wire grounded
cord sets rated for 125 Volts at 20 Amps (or greater).
Keep extension cords as short as possible, preferably
less than 15 feet long, to prevent voltage drop and
possible overheating of wires.
120 Volt AC, 20 Amp Receptacle
Use a NEMA L5-20 plug with this receptacle. Connect
a 3-wire cord set rated for 125 Volts AC at 20 Amps
(or greater) to the plug.
3-Wire Cord Set
__l.,.J
NEMA L5-20
Neutral
Hot
Ground (Green)
Use this receptacle to operate 120 Volt AC, 60 Hz,
single phase loads requiring up to 2,400 watts (2.4
kW) of power at 20 Amps. The outlet is protected by a
20 Amp push-to-reset circuit breaker.
©
__r_nd
eutral
120V
iltreen)
Use this receptacle to operate 120 Volt AC, 60 Hz,
single phase loads requiring up to 3,600 watts
(3.6 kW) of power at 30 Amps. The outlet is protected
by a 30 Amp push-to-reset circuit breaker.
120/240 Volt AC, 30 Amp Receptacle
Use a NEMA L14-30 plug with this receptacle.
Connect a suitable 4-wire grounded cord set to the
plug and to the desired load. The cord set should be
rated for 250 Volts AC at 30 Amps (or greater).
4-Wire Cord Set
(Neutral)
NEMA L14-30
/_
Ground (Green)
Use this receptacle to operate 120 Volt AC, 60 Hz,
single phase loads requiring up to 3,600 watts
(3.6 kW) of power at 30 Amps or 240 Volt AC, 60 Hz,
single phase loads requiring up to 7,200 watts
(7.2 kW) of power at 30 Amps. The outlet is protected
by a 30 Amp push-to-reset
circuit breaker.