WICKED SMART TIP
BATTERY TESTING AND DIAGNOSTICS. The battery
charger will not begin delivering any current to the battery(s)
until the battery charger detects a 'stable' battery. A 'stable'
battery means the eyelet terminal connectors are connected
to the battery with the correct polarity (POSITIVE-TO-
POSITIVE, NEGATIVE-TO-NEGATIVE) and have a tight,
clean connection to the battery being charged. If the battery
is not stable for at least three (3) seconds, the battery charger
will not begin charging the battery and the battery charger
will go into an ERROR condition. If the battery is connected
in reverse polarity, it is considered an 'unstable' battery and
the ERROR LED will illuminate until the ERROR is cleared by
reversing the eyelet terminal connectors.
TECHNICAL SPECIFICATIONS
Battery Banks
Amps/Bank
Total Amps
Input Voltage AC
Working Voltage AC
Nominal Voltage
Efficiency
Charging Voltage
Back Current Drain
Charger Type
Type of Batteries
Battery Chemistries
Battery Capacity
Housing Protection
Output Leads (Length)
AC Cord (Length)
Dimensions (L x W x H)
Excluding Cords
GEN1
1
10A
10A
110-120VAC, 50-60Hz
70-130 VAC, 50-60Hz
12VDC
~90%
14.4V
<5mA
Ripple
<2%
8 Step, Fully Automatic, Switch-Mode
12V Lead-Acid
Wet, Gel, MF & AGM
25-230Ah; Maintains All Battery Sizes
IP68
Cooling
Natural Convection
6.3 Feet
6.0 Feet
7"x6"x3.3"
Weight
6.4lbs
GEN2
2
10A
20A
12VDCx2
8.5"x6.5"x3.3"
8.7lbs
GEN3
GEN4
3
4
10A
10A
30A
40A
12VDCx3
12VDCx4
11.5"x8.5"x3.25"
14.5lbs
15.6lbs