CAUSE
Unit is unplugged
Starter button or bail improperly used
Overload protection switch has popped out
ACTION
Make sure that extension cord is securely plugged into
cultivator's
cord outlet receptacle on one end and a 110V
outlet on the opposite end.
Press starter button and hold it in while squeezing bail against
the handle.
Depress overload protection switch. Follow starting instructions
NOTE:
For repairs beyond the minor adjustments
listed above, contact your nearest Troy-Bilt Parts & Repair center
(1-800-520-5520)
or other qualified service dealer for an adjustment.
Engine Type ................................................................................
AC 120 Volts Electric
Operating RPM ..................................................................................
up to 8,000 rpm
Ignition Switch
............................................................................
Bail Lock Safety Button
Amperage
...........................................................................................
6.5 Amps
Overload Protection
..........................................................................
120 V 5 amp Breaker
Drive Shaft Tube .....................................................................................
Steel Tube
Handle .............................................................................................
Steel Tube
Cultivating Path Width (Maximum)
...............................................................
9 inches (22.86 cm)
Cultivating Depth (Maximum)
...................................................................
6 inches (15.24 cm)
Approximate Weight (no fuel)
.....................................................................
27 lb. (12.25 kg)
All specifications
are based on the latest product information
available at the time of printing. We reserve the right to make
changes at any time without notice.
10