Minimum Clearance Requirements For Non-Combustible Surroundings - Bartscher GLO-RAY GRH Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION

Minimum Clearance Requirements for Non-Combustible Surroundings

Corded Units with Built-In Switches
Models
(A)
GRa and
253 mm
GRaL
(10")
GRaH and
279 mm
GRaHL
(11")
Hardwired Units with Built-In Switches
Models
(A)
GRa and
203 mm
GRaL
(8")
GRaH and
GRaHL
253 mm
with Infinite
(10")
Heat Control or
Indicator Light
GRaH and
GRaHL
203 mm
with ON/OFF
(8")
Toggle Switch
Hardwired Units with Remote Switches
Models
(A)
GRa and
203 mm
GRaL
(8")
203 mm
GRaH and
GRaHL
(8")
(B)*
(C)
---
76 mm
---
(3")
---
76 mm
---
(3")
(B)*
(C)
---
25 mm
---
(1")
---
25 mm
---
(1")
---
25 mm
---
(1")
(B)*
(C)
0 mm
0 mm
(0")
(0")
0 mm
0 mm
(0")
(0")
Pass-Through Shelf
Counter
Non-Combustible Clearance Requirements
Dual Units with Built-In Switches
Models
(A)
GRa-XXD
GRaH-XXD
253 mm
(10")
GRaL-XXD
GRaHL-XXD
Dual Units with Remote Switches
Models
(A)
GRa-XXD
GRaH-XXD
203 mm
GRaL-XXD
(8")
GRaHL-XXD
* Must be a pass-through application, not allowed with back
wall installation.
8
C
B
A
(B)*
---
25 mm
---
(B)*
76 mm
(3")
Form No. GRCEM1-1115
(C)
(1")
(C)
0 mm
(0")

Publicidad

Tabla de contenido
loading

Tabla de contenido