Service Settings - Tylo CC 300 Manual De Instalación Y Empleo

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
LCD brightness.
Select [MENU] in the Normal display, [Service] and then [Display].
Highlight [(Brightness (%)] and press the middle button. The highlighted
text then turns dark blue and the value for the brightness of the LCD
display can be changed. Press [OK] to confirm.
LCD brightness in sleep mode.
Select [MENU] in the Normal display, [Service] and then [Display].
Highlight [Stand by (%)] and press the middle button. The highlighted text
then turns dark blue and the value for the brightness of the LCD display
when the panel is on stand-by can be changed. Press [OK] to confirm.
(The factory setting is 30%.)
Countdown to LCD sleep mode.
Select [MENU] in the Normal display, [Service] and then [Display].
Highlight [Stand by time] and press the middle button. The highlighted
text then turns dark blue, and you can reduce or extend the length of time
it takes before the LCD display dims after the panel has switched to
stand-by. Press [OK] to confirm.
Service.
See SERVICE SETTINGS
Code lock.
Select [MENU] in the Normal display and then [Service]. Use the arrow
keys to move to [Code lock] and press [OK]. Enter the desired code. Use
the arrow keys to display the correct combination and confirm with [OK].
The security code function is automatically activated during programming
and the panel shows Normal display.
To return to unlocked mode, repeat the above procedure and set the
code to 0000.
It is not possible to change any settings when the security function has
been activated. It is possible, however, to switch both the facility and the
lighting on and off. The bathing cycle runs for the time indicated in the
Service menu under [Time outside timer]. (Factory setting: 1 hour).
A general code that always works is 1995.
IMPORTANT! Program all settings before activating security code.
Language.
Select [MENU] in the Normal display and then [Service]. Select
language. Use the arrow keys to select the required language and then
press [OK].
Clock.
Select [MENU] in the Normal display and then [Service]. Select [Set
clock). First use the arrow keys to set the right day and confirm with [OK].
Then set the correct time; first the hour and then the minutes.
Factory settings.
Select [MENU] in the Normal display and then [Service]. Select [Factory
settings]. Use the arrow keys to select [Yes] or [No] and then press [OK].
Selecting [Yes] deletes all your own programmed settings and the panel
reverts to the original factory settings.

SERVICE SETTINGS

Service.
The Service menu enables the bathing facility attendant to change
certain settings such as the maximum bathing temperature. However, we
recommend that the original factory settings are always retained. The
Service menu is protected by a code to prevent unauthorised users from
changing factory settings. In the Normal display press [MENU] and then
[Service]. Select [Service] and enter the code 124.
System settings.
Maximum running time
[Max running time (hrs)] – The running time that was set at the initial
start-up. This setting does not apply when the equipment has been
programmed. Adjustable from 1–24 hrs. Factory setting: 3 hrs.
Temperature unit
[Temperature (°C/°F)] – This feature enables you to display temperatures
in Celsius or Fahrenheit.
Test menu
CC 300
The Test menu is used only for trouble-shooting and technical support
via Tylö.
Max temperature.
[Max temp (°C/°F)] – Used to set the maximum temperature to which the
facility can be programmed.
Temperature reduction during stand-by.
[Temp reduction Stand by (°C/°F)] – This is where you indicate the
reduction in temperature from the programmed bathing temperature to
the stand-by temperature. Factory setting: 30°C.
Max. running time during stand-by.
[On time Stand by (mins)) – The duration of the bathing cycle that is
initiated when the ON button is pressed while the facility is on stand-by.
Factory setting: 60 minutes.
Max running time outside programmed time.
[Time outside timer (mins)] – The duration of the bathing cycle outside
code-locked, programmed time.
Removing limescale
[De-scaling (hrs)] – Timer function that records total operating time and
counts down to signal when it is time to clean the equipment from any
limescale deposits. Factory setting: 40 hours.
In the event of a problem, please contact your Tylö
retailer.
© This content may not be reproduced in part or in whole without written permission from Tylö.
Tylö reserves the right to amend specifications of materials, construction and design.
7

Publicidad

Tabla de contenido
loading

Tabla de contenido