Operation Of The Electronic Con- Troller - Sammic SL-1100 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
MODELS
This manual describes the installation, ope-
ration
and
maintenance
1100/B/BP and SL- 1220/B/BP dishwashers.
The model reference and its specifications
are shown on the identificacion plate loca-
ted in the machine.
Models "B": equipped with a drain pump
Models "BP": equipped with an Air gap-
Break Tank and rinsing booster pump.
These machines have been designed and
manufactured in accordance with the follo-
wing
European
directives
89/392/EEC and 73/23/EEC.
These appliances comply with the EN55014
and EN55104 standards for the suppres-
sion and exemption of radio- frequency
interferences.
INSTALLATION
For optimum performance and long service
life of the machine, follow the instructions
contained in this manual rigorously.
W
ATER CONNECTION
Before proceeding with the installation of
the machine, check and make sure that:
1. The mains water connection is within
1.50m from the foreseen location of dis-
hwasher.
2. At its end on the machine side, the water
supply connection is equipped with a 3/4"
GAS stopcock for the coupling of the water
supply hose supplied with the machine.
3. The dynamic pressure of the water sup-
plied to the machine is not less than 2
bar (200kPa) and not greater than 4 bar
(440kPa).
4. Inlet water flowrate is at least 20l/min.
5. For good washing results, the hardness
of water (lime) must not exceed 10
hydrotimetric degrees.
6. In places where the water pressure is hig-
her than the specified one, it will be
necessary to incorporate a pressure redu-
cer to bring the service pressure within the
limits of 2 to 4 bar (200 and 400kPa).
7. If the water pressure is less than 2 bar, it
will be necessary to install a pressure
booster.
8. Avoid bottlenecks with hoses when
making this installation.
9. On models with gravity drainage, con-
nect the drain pipe of an O.D. of 30mm
to the sewage system. The distance from
the sewage system to the machine base
shall not exceed 280mm.
6
EN
10.On models "B" equipped with a drain
pump, the distance from the sewage
system to the machine base shall not be
greater than 1m.
of
the
SL-
11. In order to ensure complete drainage,
it is essential that the machine is even.
To level it, undo or screw in the leve-
lling feet.
12. Models "BP": The inlet solenoid valve
includes a flowrate controller different
from the standard model, as stated on
the spare parts list. This model is capa-
ble of operating at an input water pres-
sure ranging from 0.7 to 5 bar and a
minimum supply of 7l/min.
for
safety:
M
ACHINE INSTALLATION WITH A WATER SOFTENER
If the lime content of the water is greater
than 10 degrees of hardness, install a
SAMMIC water softener. The installation
instructions of this device come with it.
Avoid bottlenecks before and after this ins-
tallation as flow would be reduced produ-
cing loss of pressure.
M
ACHINE INSTALLATION WITH A BOOSTER PUMP
Where the inlet water pressure is lower than
2 bar (200kPa), install a booster pump.
The booster pump may be installed any-
where near the machine, approaching the
water piping and corresponding 3/4" cock
to the device. Ensure that the water cock is
still accessible.
Connect one end of the booster pump to
the water cock and the other end to the
hose supplied with the machine.
E
LECTRIC INSTALLATION
Single- phase machine: SL- 1100
Check whether the voltage of the machine
coincides with the mains voltage.
1. Install a 40A (1P+ N) switch of the magne-
tothermal type. The machine is equipped
with a cable of a cross section of 3x6mm²
and 2m in length. This cable must be
connected directly to the switch.
Three- phase
1200
2. Check whether the voltage of the machine
coincides with the mains voltage. Series-
production machines are delivered, pre-
pared with a 400V/3N connection.
3. Install a 25A (3P+ N/400V) or 35A
(3P/230V) magnetothermal switch. The
machine is equipped with a cable of a
cross section of 5x6mm² and 1.70m in
length. This cable must be connected
directly to the switch.
4. If the motor rotates in the opposite
direction (producing abnormal noise on
machines: SL- 1100/SL-
model SL1200), it is necessary to invert
two phases of the power supply.
5. Changing connections for a 230V/3-
phase supply:
· Disconnect the neutral (blue wire) of the
power cable from the connecting strip.
· Connect the bridge to the connecting
strip as shown on the wiring diagram.
· Change the connections at the heating
resistor of the boiler and at the heating
resistor of the tank, placing the bridges
included in the supply as shown on the
wiring diagram.
· Change the connections in the motor
terminal box.
· EARTHING is OBLIGATORY. Moreover,
the machine includes an external screw
for its connection to a ground equipo-
tential system.
OPERATION OF THE ELECTRONIC CON-
TROLLER
Technical description of the control
panel: Figure A
D
(2)
ISPLAY
When the machine is powered up with main
switch (1), the selected machine configura-
tion number appears on the display for 2
seconds, immediately followed by the tub
temperature. A pressure on key (3) retrie-
ves the boiler temperature.
T
S
EMPERATURE
ELECTOR
Readings in display (2) will change as key
(3) is pressed on successively, alternating
the tub temperature (LED (a) on) and the
boiler temperature (LED (b) on).
C
T
S
(4)
YCLE
IME
ELECTOR
By pushing key (4) repeatedly, you can
select any of three wash cycle times. Light
indicators show the selected cycle:
(d): Short Cycle.
(e): Medium Cycle.
(f): Long Cycle.
Choosing the adequate cycle depends on
how soiled trays and utensils are. The dir-
tier they are, the longer the cycle has to be
for an intensive, thorough washing.
S
C
(5)
TART
YCLE
If you press this key, the wash cycle starts
and the associated LED (g) turns on. At the
(3)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sl-1100bSl-1100bpSl-1200Sl-1200bSl-1200bpSl1100 ... Mostrar todo

Tabla de contenido