3. STARTING UP
After completing the connections as indicated and checking the electrical connections
carefully, turn ON the mains power supply and check that the system is functioning
correctly, as explained below.
3.1 FUNCTIONING TESTS
When all the connections have been made, it is necessary to check the automation
system, checking that the automation opens when you press the start push-button. If it
closes, invert the motor connections.
3.2 TRIMMER ADJUSTMENT
Trimmer P1 – This trimmer is used to adjust the automation work time. The adjustment
range is between 0 and 180 seconds; we recommend that you set this time at
approximately 5 seconds higher than the time required to complete the stroke.
Trimmer P2 - This trimmer is used to adjust the pause time before automatic closing of
the automation, when the automatic functioning mode has been selected. The adjustment
range of the pause time is between 0 and 120 seconds
Trimmer P3 - This trimmer is used to adjust the thrust force of the actuators to the
structure of the gate. To make this adjustment, follow the procedure below carefully.
Note - These adjustments are memorised by the microprocessor in real time, also when
the device is functioning.
3.3 OPERATING PROGRAMMING
It is now possible to program the device. The DIP-SWITCH SW1 is used to select the
operating mode and other accessory functions.
CAUTION – Every time you program the device, disconnect the electrical power supply
to cancel the previously set program.
DIP-SWITCH 1 – Reverse stroke enabling/disabling. This function is used to release
the electric lock, also in diffi cult conditions.
Operating process: when the opening command is given, the motors are driven for
approximately 1 second in closing mode; this is followed by a stop of approximately
0.5 seconds and then the electric lock power supply is enabled for 1.5 seconds and the
opening command is generated at the same time. If there is no electric lock, do NOT
enable this function. The reverse stroke is only enabled if the stand-by condition has
the gate completely closed; it is not enabled in the case of inversion from the closed
position to the open position.
ENGLISH
DIP-SWITCH SW1
S1
REVERSE STROKE
YES
ON
OFF
NO
PRE-FLASHING *
S6
ON
YES
OFF
NO
Note:
The flashing light only works when
the flashing light (24 V) is connected
to terminals 10 and 11.
S7
PAUSE PHOTOCELL
ON
YES
OFF
NO
DIP-SWITCHES 2 and 3 - These DIP-SWITCHES are used to select the following
operating modes.
DEAD MAN MODE. This operating mode requires the physical presence of a human
operator, who opens and closes the gate and the input of terminal 6 is used as the
closing start (use a N.O. contact). To open the gate, press the start push-button and
hold it down (opening input). When the push-button is released, the gates are blocked.
To close the gate, press the close push-button and hold it down; if the photocells are
obscured, the device blocks the gates. In this case, the operator must release the push-
buttons and press either close or open. This is also the case if the two push-buttons
are pressed at the same time.
S2
S3
OPERATING MODE
ON
ON
AUTOMATIC
OFF
ON
SEMIAUTOMATIC WITH STOP
ON
OFF
SUPER AUTOMATIC
OFF
OFF
DEAD MAN
S4
S5
GATE CLOSING DELAY (sec.)
OFF
OFF
0
OFF
ON
3
ON
OFF
9
ON
ON
16
5