i
I (
) Using the appropriate tool, insert seal "L1" between
glass panel "D" and glass panel profile "B", making sure it is in the
correct position.
i
I (
) Position compensator "E" on the wall, ac-
cording to the given measurements.
Check that it is level and mark the holes for drilling holes as shown.
Measurements refer to the edge of the shower tray, not
the wall.
i
I (
) Remove the compensator, drill the holes and
insert the dowels. Apply silicone to the rear part of the compen-
sator as shown (
). Then replace the compensator and, af-
ter checking that it is level, fasten it as shown (
i
I (
) Fasten the foam rubber protective strip to the
part of the glass panel that faces the wall.
i
I (
) Then insert glass panel "F" into the fixture panel
as shown and slide it until the required distance is obtained, check-
ing that it is perpendicular with the fixture panel (
i
I (
) Drill holes in compensator "G", using the holes
shown as a guide.
i
I (
) Line compensator "G" up with the profile as
shown and mark the holes for drilling.
i
I (
) Remove the compensator, drill holes and in-
sert the dowels. Then replace the compensator and fasten it as
shown (
).
i
I (
) Check that the glass panel and the column are
perpendicular. Then, using as a reference the holes compensator
"G", after checking for level, drill the profile of glass panel "F"; then
attach the compensator with the screws indicated.
The maximum projection allowed for the glass panel in relation to
the compensator is 10 mm.
i
I (
) Using the appropriate tool, insert seal "L2" be-
tween the glass panel and the fixture panel, making sure it is in the
correct position.
i
I (
) Position compensator "G" on the wall, ac-
cording to the given measurements.
Check that it is level and mark the holes for drilling holes as shown.
Measurements refer to the fixture panel wall.
i
I (
) Remove the compensator, drill the holes and
insert the dowels. Apply silicone to the rear part of the compen-
sator as shown (
). Then replace the compensator and, af-
ter checking that it is level, fasten it as shown (
i
I (
as shown and insert the crystal "H" in the compensator "G (
).
For the
that the edges of the profiles of the two glass panels match perfect-
ly.
i
I (
).
compensator as shown and insert the glass panel "I" in the com-
pensator "E".
For the
that the edges of the profiles of the two glass panels match perfect-
ly.
i
I (
).
draulic beam (B).
Screw the rainfall shower head into the hydraulic beam and se-
cure all by tightening the headless screws (
Fasten the beam to the column with the nut and O-ring provided
(
).
are installed in the correct direction
I (
) Fasten the glass panels using the components provid-
ed with the glass panels, following the indicated supply diagram.
I (
) If the glass panels are not level, turn the adjustment
ring nuts.
I (
) Once the glass panel is perpendicular, fasten the cross-
piece.
I (
) Make the plumbing connection shown in the figure,
placing the gasket.
i
I (
insert the bushes into the hinges (
i
I (
line it up with glass panel "H", inserting the door hinges into the
ones on the fixed glass panel, and fasten them with the threaded
pins (
i
I (
) Check for perfect closing of the magnets, as well as the
distance (which must be constant) between the lower edge of the
door and the tray (with the plastic spacer). If this does not occur,
turn the adjustment ring nuts (
kets, use a wood block and a rubber mallet (
).
When adjustment is complete, tighten the screws and screw in the
coverings (
) Apply silicon on the inner part of the compensator
) Apply silicone on the inner part of the
) Screw the glass panel support (A) into the hy-
for the
(
) Attach the handles to the door as shown. Then
) Insert the plastic spacers under the door. Then
).
).
, check
, check
).
, make sure the washers "R"
).
).
) or, on the magnetic gas-
).