NOTES
22
OPERATION
1. Perform the test
using your Auto
Meter hand-held
tester.
2. When the test is
complete, point the
tester in the gereral
direction of the IR-1
Press the print key
on the tester panel.
The test number and
results indicated
on the tester LCD
will print out on the
printer connected
to the XTC-160 with
the IR-1.
3. LED Indications
• Top LED
Solid Green -
Ready to accept
print job
Blinking Green -
Receiving IR print
data
Solid Red - Print
error. Resend print
data. Also make
sure the print option
setting on the
hand held tester is
set to XTC-160/
PR-16.
• Bottom LED
Off - Idle mode
Solid Green -
Sending data to
printer.
Solid Red - Printer
not ready.
3