Power Supply Cord
Direct Wire
Fire Hazard
Use a new UL listed 30 amp power supply cord,
Use a UL listed strain
retiefo
Disconnect
power before making e_ectrical connections,
Connect neutrat wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected
to
green ground connector.
Connect remaining
2 supply wires to remaining
2 terminals
(gold).
Securety tighten
al electrical
connections,
Failure to do so can result in death, fire, or
electrical
shock.
Fire Hazard
Use 10 gauge solid copper wire,
Use a UL listed strain relief,
Disconnect
power before making electrical
connections.
Connect
neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected
to
green ground connector,
Connect
remaining
2 supply wires to remaining
2 terminals
(gold).
Securety
tighten
all electrical
connections,
Failure to do so can result in death, fire, or
electrical
shock,
1. Disconnect
power.
2. Remove the hold-down
screw and terminal block cover.
D
3. Install strain relief.
Style 1: Power supply cord strain relief
Remove the screws from a %" (1.9 cm) UL listed strain
relief (UL marking on strain relief). Put the tabs of the two
clamp sections into the hole below the terminal block
opening so that one tab is pointing up and the other is
pointing down, and hold in place. Tighten strain relief
screws just enough to hold the two clamp sections
together.
/
A. Neutral ground wire
B. External ground conductor screw
C. Center, silver-colored
terminal block screw
D. Terminal block cover and hold-down
screw
A. Strain relief tab pointing
up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing
down