Installation and start-up

Choosing the installation location
To ensure that the control panel and the proximity chip key reader work correctly, ensure
that there are no wires/cables, pipes, metal reinforcements or other relevant installation
components within approx. a 50 cm radius of the intended installation location.
Electrical wires and metal objects in particular may disrupt or adversely
affect the functions or the behaviour of the proximity chip key reader.
Installing the base plate
1.
Open the wireless control panel housing by
removing the screws on the bottom.
2.
Use the base plate as a drilling template and
mark the holes on the wall in the previously
selected installation location.
When marking out the drill holes, make
sure there are no electrical wires or
cables, pipes or other important
components behind the mounting
location!
3.
Drill the holes and insert the screw anchor.
4.
During operation with an external power supply, insert the cables for the power
supply unit from behind into the base plate on the control panel.
5.
Screw the back of the housing to the wall.
Installation and start-up
EN 11