Descargar Imprimir esta página

Signs And Symbols Used - Abicor Binzel ABIMIG A Instructivo De Servicio

Ocultar thumbs Ver también para ABIMIG A:

Publicidad

Idiomas disponibles

Idiomas disponibles

®
ABIMIG
Type
Type of
cooling
Single
circuit
®
ABIMIG
A LW
155
Air
255
Air
305
Air
355
Air
405/
Air
415/455
®
ABIMIG
A T LW
155
Air
255
Air
305
Air
355
Air
405/
Air
415/455
®
ABIMIG
W / W T
340
Liquid
440
Liquid
540
Liquid
Tab. 3
Product-specific torch data (EN 60 974-7) ABIMIG
Standard length L
Coolant connection
Cooling unit power
Control lead
Tab. 4
Cable assembly

3.2 Signs and symbols used

The following signs and symbols are used in the operating instructions:
BAL.0402.0 • 2018-08-24
Load
DC
Standard
Pulse
light arc
CO
M21 M21
2
A
A
A
%
170
170
60
230 220
60
280 260
60
330 310
60
400 350
60
190 180
60
240 220
60
290 260
60
340 320
60
400 370
60
400 350 350
100 0.8 - 1.2
500 450 350
100 0.8 - 1.6
600 550 400
100 1.0 - 1.6
Wire 
Gas flow
Max.
supply
temp.
mm
l/min
°C
0,6 - 1,0
0,8 - 1,2
0,8 - 1,2
1,0 - 1,6
1,2 - 2,4
0.6 - 1.0
10 - 18
0.8 - 1.2
11 - 18
0.8 - 1.2
12 - 18
1.0 - 1.6
10 - 20
1.2 - 2.4
10 - 20
10 - 20
50
10 - 20
50
10 - 20
50
®
A / A T LW and W / W T
3.00 m/4.00 m/5.00 m
Plug-in nipple, nom. diam. 5
Min. 800 W
2-wire
3 Product description
Cooling
Flow
pressure
Min.
Min. Max.
flow rate
l/min
bar
bar
1.5
1.5
3.5
1.5
1.5
3.5
1.5
1.5
3.5
EN - 5

Publicidad

loading

Este manual también es adecuado para:

Abimig a t lwAbimig wAbimig w t