Insulated-Hole Mounting - Magontec CORREX MP 1.9- 900 Instrucciones De Uso

Sistema de corriente impresa para calentadores-acumuladores de agua inoxidable
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

7.2
CORREX
®
MP 1.9-900 for insulated-hole mounting
Note: Observe the instructions set out in chapter 2.3 above.
7.2.1 Safety instructions for fitting:
1. Remove any existing magnesium protection anode before installing the
CORREX
2. Never connect the plug-in potentiostat to magnesium protection anodes.
3. The titanium anode must not be in direct contact with internal tank components
or with the tank wall. The quality of the insulation must be checked with a
suitable measuring instrument (e.g digital multimeter or CorroScout
During this measurement, the titanium anode must not be immersed in water.
4. The function of the CORREX
parts are safely connected by metallic conductors. The quality of the galvanic
connections must be checked with a suitable measuring instrument (e.g
digital multimeter or CorroScout
5. Use only the original connecting cables.
6. Never extend the connecting cables: otherwise risk of connection with
wrong polarity and thus of increased corrosion.
7. Check before commissioning that the cables are not interchanged.
Interchanging the cables results in increased corrosion.
8. Use only the original sealing material.
Note: If the CORREX
existing holes of former insulated-hole mounted magnesium anodes can be
used.
7.2.2 Sketch: Fitting and commissioning
The illustration on the fold-out page (chapter 11.1) of this manual shows an
example of the installation procedure for a CORREX
illustration shows the installation in a flange-type cover. The actual situation
depends on tank type, tank size, type of anode and connecting cables used.
Note: Leave the fold-out page (chapter 11.1) open when installing the system.
The following parts are need for fitting:
1. Titanium anode (1)
2. Connecting cables (chapter 1.2, scope of supply (3))
3. Plug-in potentiostat (chapter 1.2, scope of supply (2))
4. 1 Seal (4)
5. 1 Insulation sleeve with collar (5)
7. 2 Hex nuts M8 (7) and (9)
8. 1 Tooth lock washer with tab connector 6.3 x 0.8 mm (8)
®
MP 1.9-900 system (in case of retrofitting).
®
MP 1.9-900 system is installed by way of retrofitting, any
Operating Instructions CORREX
®
MP 1.9-900 system is only ensured if all electrical
®
500).
®
MP 1.9-900
®
®
MP 1.9-900 system. The
500).
29

Publicidad

Tabla de contenido
loading

Productos relacionados para Magontec CORREX MP 1.9- 900

Tabla de contenido