4 Scope of delivery
4 Scope of delivery
• Fume extraction system with mains connection of
115 V/230 V
• Rubber connector
Tab. 5
Scope of delivery
Order the equipment parts and wear parts separately.
The order data and ID numbers for the equipment parts and wear parts can be found in the current catalogue. Contact details
for advice and orders can be found online at www.binzel-abicor.com.
4.1 Transport
Although the items delivered are carefully checked and packaged, it is not possible to fully exclude the risk of transport
damage.
Goods inspection
In case of complaints
Packaging for returns Where possible, use the original packaging and the original packaging material. If you have
Tab. 6
Transport
4.2 Storage
For ambient conditions for storage in a closed environment, see:
Tab. 3 Ambient conditions for transport and storage on page EN-9
5 Functional description
The FES-200 W3 fume extraction system forms part of the welding system and is intended for manual torch use. The device
corresponds to the welding fume separation class W3. It is designed for the separation of fumes generated during welding
or thermal cutting of steels with alloy constituents such as nickel or chrome <30% and high-quality steels. The operating,
maintenance and servicing conditions must be observed.
DANGER
Risk of fire
Before installing and operating the fume extraction system, please observe the following:
• The extraction of welding fume during welding of oil-wetted parts is not allowed.
• It is not allowed to install or operate the system in areas subject to dust or gas explosion hazards.
CAUTION
• Before putting into operation, it must be checked if the operating voltage given on the nameplate corresponds to the
mains voltage.
NOTICE
• Use the FES-200 W3 fume extraction system only in areas with sufficient ventilation.
• The fume extraction system is equipped with a safety device to monitor the minimum air volume flow to be extracted. A
manometer is used for monitoring. The point at which the minimum volume flow is reached is marked on the dial scale.
If the manometer indicates a higher vacuum (>180 mbar), the filter must be cleaned.
EN - 10
Use the delivery note to check that everything has been delivered.
Check the delivery for damage (visual inspection).
If the delivery has been damaged during transportation, contact the last carrier immediately.
Retain the packaging for potential inspection by the carrier.
questions concerning the packaging and safety during shipment, please consult your supplier,
carrier or transporter.
• Extraction hose (l=5.00 m)
• Dust collecting bag (10 pieces)
BAL.0335.0 • 2019-08-16
FES-200 W3