FES-200 W3
1
16
15
14
13
12
11
10
1
Rubber gasket
2
Turbine
3
Mounting screws
4
Compressed air connection for
dedusting with pressure relief
valve
Fig. 2
Functional description
Harmful fumes are produced during the welding process. A permanent filter located in the filter housing removes the welding
fume particles from the absorbed air. The cleaned air is led back into the work area via the exhaust casing (12).
If the minimum volume flow is not reached, the manometer (10) indicates a high value and an acoustic signal sounds. The
filter must be then cleaned with compressed air. During the dedusting procedure, the exhaust fume deposits are removed
from the filter elements and the filter is refreshed.
The separated dust is collected in the dust collecting drawer (8).
NOTICE
• The dust collecting drawer (8) must be emptied before and after each dedusting of the filter.
• After each use, the dust collecting drawer must be checked.
• In case of a filling level of 2/3 or more, the dust collecting drawer must be emptied according to the regulations.
5.1 Emptying the dust collecting drawer on page EN-12
The FES-200 W3 is equipped with an automatic Start-Stop system. Use the start-stop pliers to switch on the fume extraction
system automatically by fixing it to the cable assembly of the welding device.
The rocker switch (11) is used to switch the fume extraction system on and off.
BAL.0335.0 • 2019-08-16
2
3
5
Filter cartridge
9
6
Extraction hose
10 Manometer
connection
11 Rocker switch
(intake fitting)
7
Seal plug
12 Exhaust casing
8
Dust collecting drawer
5 Functional description
4
5
6
7
8
9
Knurled nuts
13 Power cable connection
14 Voltage circuit breaker
15 Start-stop pliers connector
(Manual-0-Auto)
16 Counter nut
EN - 11