Siemens Sitrans LR250 Guia De Inicio Rapido página 10

Ocultar thumbs Ver también para Sitrans LR250:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 113
1. Intrinsically Safe wiring method (barrier required)
SITRANS LR250
7ML1234-56789-0ABC-D
Serial No: GYZ / S1034567
Encl.: NEMA / TYPE 4X, 6, IP67, IP68
Amb.Temp.: – 40 °C to 80 °C
Power Rating: 24V
Nom., 30 V
Siemens Milltronics Process Instruments Inc., Peterborough
Made in Canada
SITRANS LR250
7ML1234-56789-0ABC-D
Serial No: GYZ / S1034567
Encl.: NEMA / TYPE 4X, 6, IP67, IP68
Amb.Temp.: – 40 °C to 80 °C
Power Rating: 24V
Nom., 30 V
Siemens Milltronics Process Instruments Inc., Peterborough
Made in Canada
Approval Rating
ATEX II 1 G, EEx ia IIC T4
ATEX II 1 D, EEx tD A20 IP67 T90 °C
IECEx SIR 05.0031X, Ex ia IIC T4, Ex tD A20 IP67 T90 °C
FM/CSA:
Class I, Div. 1, Groups A, B, C, D
Class II, Div. 1, Groups E, F, G
Class III
• For power demands see
• For wiring requirements:
Europe/International: Follow local regulations.
US/Canada:
• Use appropriate conduit seals to maintain IP or NEMA rating.
• Recommended Intrinsically Safe barriers are listed under
Active barriers (repeating barriers)
on page 8 and
Instructions specific to hazardous area installations
• Refer to
: Selecting a suitable PLC input module, power supply, or barrier requires knowledge
Note
about Intrinsic Safety and the application. It is the responsibility of the installer to ensure that
the intrinsically safe installation complies with both the apparatus approval requirements
and the relevant national code of practice.
Passive Shunt Diode Barriers
: A well regulated supply voltage is required.
Note
Manufacturer
MTL
MTL
Page EN-8
SITRANS LR250 (HART) – QUICK START MANUAL
Max., 4 - 20mA
Max., 4 - 20mA
Loop Voltage versus Loop Resistance
FM/CSA Intrinsically Safe connection drawing
Download
(23650653)
from the product page of our website at:
www.siemens.com/LR250 or see Appendix A: page A-1.
Part Number
787SP+ (Dual Channel)
7787P+ (Dual Channel)
II
Ui = 30 V
1 G EEx ia IIC T4
II
1 D EEx tD A20 IP67 T90°C
Ii = 120 mA
SIRA 06ATEX2358X
Pi = 0.8 W
Ci = 15 nF
Li = 0.1 mH
IECEx SIR 05.0031X
Ex ia IIC T4
HART
Ex tD A20 IP67 T90°C
I max = 120 mA
Class I, Div 1, Gr. A, B, C, D;
P max = 0.8 W
Class II, Div 1, Gr. G;
V max = 30 V
Class III
C i = 15 nF
Temp. Code : T4
L i = 0.1 mH
Exia per drawing: 23650653
IC: 267P-LR250
FCC ID: NJA-LR250
HART
WARNING:PossibleStaticHazard,DoNotRubOrCleanOnSite
Valid for:
Europe
International
US/Canada
on page 21.
Passive Shunt Diode Barriers
on page 9.
on page 10.
0518
159134
N117
7ML19985QX81

Publicidad

Tabla de contenido
loading