Technical Specifications - BFT MOOVI Serie Instrucciones De Uso Y De Instalacion

Automatismos electromecánicos para barreras vehicular
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27
I
~I
L_
~ 0
;;
o
;::
;!
:xi
o
INSTALLATION
MANUAL
2) GENERAL INFORMATION
Compact
electromechanical
barrier suitable for enclosing
private areas
and car parks and for use across entrances
used by vehicle traffic only.
Available
for entrance/exit
points between
3 and 5 metres across. Ad-
justable
electromechanical
limit switches ensure the boom stops in the
correct position.
The emergency
release for manual operation
is operated
by a lock with a
personalized
key.
The actuator is always supplied
ready for assembly on the left.
Where necessary, the opening
direction
can always be reversed with a
few simple operations.
The foundation
base mod. CBO (on request) can
be supplied to make the barrier easier to install.
Provision for accessories makes installing
them straightforward,
with no
need to drill additional
holes.
3) TECHNICAL SPECIFICATIONS
MOTOR
Power supply:
230V±10% 50Hz(*)
Max. power input:
300W
Capacitor:
811F 450V (230V): 3211F 250V (11OV)
Current demand (with accessories):
l,4A: 2.8 A
Insu lation class:
F
Internal lubrication:
lifetime greased
Max. torque:
85 Nm (MOOVI30)
250 Nm (MOOVI 50)
Opening time:
4s (MOOVI 30)
8s (MOOVI 50)
Boom length:
max. 3m (MOOVI 30)
max. 5m (MOOVI 50)
Impact reaction (Safety Edge):
stop or stop and reverse
Mechanical manual release:
personalized
key
Type of boom:
rectangular
Limit switches:
electric, built-in and adjustable
Maximum
n° of operations
in
1200 (MOOVI 30)
24hrs:
600 (MOOVI 50)
Operating temperature
range:
da -10°C a +55°C
Protection rating:
IP 24
Actuator weight (without boom):
35,6 Kg
Flashing light:
230V~ 25W max
Dimensions:
seefig.A
CONTROL UNIT
Accessories power supply:
24V~(demand
max. 180mA)
Fuses:
see figures I,J
Max. motor output:
500W
Work time:
max. 10 sec.
(*)= special supply voltages to order
4.1) FOUNDATION
PLATE (Fig.B1)
4.2) ANCHOR BOLTS (Fig.B2)
5) ACTUATOR ASSEMBLY
h,.
WARNING! The barrier
must be used only for entrance/exit
points
ill
intended
forvehicletraffic.
Pedestrians
must not beallowed
to pass
within
range of the automated
system. Make sure there is a separate
entrance/exit
just for pedestrians.
The entrance/exit
must be suitably
signposted
with the compulsory
signs illustrated
in Fig.A.
WARNING: before opening
the door, the spring must be decompressed
(vertical
boom). The door in the cabinet must face towards the inside of the
property. Standing in the middle of the entrance, facing out, if the cabinet
is on your left, the barrier is on your left: if the cabinet is on your right, the
barrier is on your right.
The actuator
is always supplied
ready for assembly
on the left.
6) Assembly
on left (Fig. A, B, C. D).
-
It is easier to install the Shearing hazard protection
kit MOOVI PRM (op-
tional extra) before the boom is assembled on the automated
system.
-
Balance the boom as illustrated
in Fig. AB.
16 -
MOOV130-50
- ALPHA 80M
7) Assembly
on right
(Fig. AA).
-
Balance the boom as illustrated in Fig. AB.
8) Boom assembly
(Fig. D).
9) BOOM BALANCING (Fig. AB).
For Moovi 30:
h,.
WARNING!
During
the closing
operation,
the balancing
spring
ill
must
never be fully compressed.
Fig.AB rif.3 shows the position
for determining
the minimum
size that the compressed
spring can be
allowed
to reach with the boom in the open position
(vertical).
10) OPTIONAL ACCESSORIES (Fig.E)
-
Foundation
base CBO
-
Shearing hazard protection
kit KIT MOOVI PRM
-
Photocell
130 fastening
post kit KIT MOOVI 130
-
Fixed end rest for boom FAF
-
Folding leg to support
boom MOOVI GA (MOOVI 50 only)
-
Cushioned folding
leg to support
boom MOOVI GAMA
-
Skirt ready assembled on boom SB
-
Safety edge BIR
-
Lights kit for booms between
3m and 4.5m long KIT MOOVI LIGHT
-
Lights kit for booms 5m or 6m long KIT MOOVI LIGHT 1
-
Top or bottom
boom covering
profile MOOVI PCA
-
SS (fig. J) Barrier open light optional
board. Works with electric
limit
switches only.
MOOVI accessories (boom length limits and balancing)
(Fig. AF)
Forfurther
information
on installing and using the accessories, refer to the
relevant instruction
manual.
11) Assembling
the shearing
hazard protection
kit MOOVI PRM (Fig.AC)
12) Assembling
the flashing
light RAY XlRAY X SA (FIG.AD)
-
Complete assembly and wiring as directed in instructions
provided for
RAY X/RAY X SA.
13) Assembling
Photocell
130 / Moovi 130 (FIG. AE).
14) ADJUSTING THE LIMIT SWITCHES (Fig. G)
15) PREPARING THE ELECTRICAL SYSTEM
WARNING: before opening
the door, the spring must be decompressed
(vertical
boom). Prepare the electrical system (fig. A), referring to the stan-
dards in force. Keep mains power connections
well separated from service
connections
(photocells,
safety edges, control devices, etc.).
WARNING! For connection
to the mains power supply,
use a multicore
cable with a cross-section
of at least 3x1.5mm 2 ofthe
kind provided
for
by the regulations
mentioned
above (by way of example,
if the cable is
not protected,
it must be rated H07 RN-F or higher, while ifit is protected
it must be rated at least H05 W-F with a cross-section
of 3x1.5mm2).
16) WIRING (FIG. F, I, J)
WARNING: Wiring must be carried out by qualified, expert personnel in a
professional
manner and in accordance with all regulations
in force, using
appropriate
materials.
BORNE
DESCRIPTION
1-2
Power supply 230V +/- 10% 50Hz (Neutral to terminal 1).
3-4-5
Motor
M connection
(terminal
4 common,
terminals
3-5
motor start and capacitor).
1-4
230V flashing light connection
7-8
START input or key selector (N.O.) with trimmer TW=max.
OPEN input (N.O.) with trimmerTW=min.
7-9
STOP button (N.e). If not used, leave jumpered.
7-10
Photocell or pneumatic
safety edge input (N.e).lf
not used,
leave jumpered.
7-11
Opening limit switch (N.e).lf not used, leave jumpered.
7-12
Closing limit switch (N.e). If not used, leave jumpered.
13-14
24 V-output to supply photocell and other devices.
15-16
Output for barrier open light / 2nd radio channel.
17-18
Antenna receiver input (17 signal 18 braiding).
19-20
PEDESTRIAN input (N.O.) with trimmerTW=max.
CLOSE input (N.O.) with trimmerTW=min.
JP4
1-2 channel radio-receiver
board connector.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Moovi 30Moovi 50

Tabla de contenido