Adjusting Brew Volumes:
Servicing:
This section covers basic instructions for replacing normally serviceable parts.
1) Replacing inlet or outlet probe seals.
Warning
Brew probes are sharp. To prevent finger injury be careful when servicing inlet and outlet probe seals.
Open brew chamber, pull inlet probe seal (located on underside of brew chamber and surrounding the inlet probe)
away from probe. Replace seal by carefully pushing the new one onto the probe. Push on sides of seal to prevent
finger injury.
To replace outlet seal, reach into the brew cup with needle nose pliers, pull seal away from the probe. To replace,
gently push on edges of seal (care should be taken not to push on probe) with needle nose pliers until seal bottoms
out on cup.
2) Replacing drip tray assembly:
Pull drip tray assembly away from brewer. To
replace, line up drip tray with internal walls of
brewer and slide into until tray hit rear wall of
cavity.
(See figure below for items 1 and 2)
ENGLISH
This option will allow you to change Brew Volumes factory
default as much as ten percent. You will be able to go up ten
percent or down ten percent.
Example: For 10 oz, if you adjust to +10, it will set the vol-
ume to 11 oz. If on the other hand, you adjust to –10, then
the volume will be 9 oz.