Cleaning and Maintenance

WARNING Brew probes are sharp. To prevent injury, do not place fingers inside the brew chamber. To reduce
foreign material from entering the brewer, keep brew chamber and reservoir lids closed.
Cleaning:
NOTE: When cleaning the unit, do not use cleansers, liquid bleach, powders, or any other substance that contains
chlorine. These products promote degradation of plastic parts. Use of these products will void the warranty.
Empty the drip tray and reservoir tank as needed and wash in a solution of dish detergent and water, rinse
thoroughly.
All external parts can be cleaned with a soft, damp cloth. Do not use any abrasives. They will scratch the external
surfaces. Do not immerse machine in water. Do not place brewer into a dishwasher.
Draining: This action will clear water from the brewer.
Power off brewer. Allow brewer to cool. Close water supply valve (Auto-Fill only) and disconnect water line.
Remove and empty reservoir.
Place a cup under the brew chamber, hold down reservoir detection switch and start a brew sequence.
Continue brew sequence until water stops flowing into the cup or until Water Flow Error is displayed.
Remove back panel, uncap drain line and drain tank. Recap and replace back panel.
:
Descaling
1. Close water supply valve (Auto-Fill models only), empty reservoir, empty brew chamber.
2. Fill reservoir with 72 oz. of distilled white vinegar.
3. Using the 12 oz. cycle, operate brewer until "Fill Reservoir" notification appears.
4. Power off brewer – Empty reservoir and rinse thoroughly. Allow brewer to remain off for 3 hours before
performing Step 5.
5. Remove back panel, uncap and drain tank. Recap and replace back panel.
6. Fill reservoir with fresh water and return to brewer.
7. Flush brew chamber with 12 oz, of fresh water. Close brew chamber when finished.
8. Power on brewer, open water supply valve (Auto-Fill models only).
9. Follow on screen instructions and prime brewer.
10. Proceed with 12 oz brews until water returns to normal smell and taste.
11. Allow system to refill automatically with plumbing.
Troubleshooting
The table below lists probable causes and solutions for the most common issues that may be encountered during
operation of the Single Cup Brewer.
WARNING
Disconnect power to electrical equipment any type service of brewer is required.
Make sure that brewer is unplugged before servicing.
If electrical testing is required, proceed with extreme caution.
If brewer requires disassembly, make sure that all parts are properly replaced and that all tags and/or safety labels
are replaced as well.
Brew probes are sharp. To prevent injury, do not place fingers inside the brew chamber.