Minimum distances
The following minimum distances to furniture and other flammable objects as well as to walls must be
maintained for safety reasons:
Wall installation:
•
to cover..................................2cm
•
to side walls ...........................2cm
•
to floor....................................2cm
(for practical reasons, we recommend to leave a gap of approx. 15cm at the bottom so that the
floor below the heater can be easily cleaned)
•
to front cover .......................10cm
Ceiling installation:
•
to side walls .........................10cm
•
to front cover .......................10cm
•
minimum ceiling height .....1.90m
Recess installation:
•
to all sides .............................2cm
•
to front cover .......................10cm
•
recess depth......................... 59mm (glass surface flush to wall)
The wall bracket ensures that there is a distance of 31mm between the back of the appliance and the
wall. The depth of the appliance including wall bracket is 59mm.
Distances for attachment of wall bracket
To ensure safe fixture of the appliance, you must use the holes designated for the chosen installation
option as shown in the drawings below. For vertical installation, the holes in the long rail sections are
used; for horizontal and ceiling installation, the holes in the short rail sections are used.
25