- EN -
System message
Functions that are still
available
Motor blocked
None
Er44
(The control system
attempted to start up the
motor three times - 5 times
per attempt)
More than 960 cleaning
Er55
cycles in 48 hours
Switch element for rinsing
None
Er66
pump in the control system
overheated
The filter pump is not
Er88
delivering water.
62
Possible cause
Filter drum rotating sluggishly or jammed
The lips of the drum seal were squeezed
when the drum was installed.
The drum load is distributed unevenly
− Manual cleaning
Temporary heavy soiling
− Automatic mode
− Start-up phase of the filter system (e.g.
during the first start-up)
− Time-dependent
cleaning
− Fish are spawning
Pond heavily soiled
Screen elements heavily soiled
Insufficient cleaning effect due to soiled
nozzle
Water level in the system too high:
− Outlet pipes soiled
− Outlet opening too small
− Max. flow rate exceeded
− A large amount of dirt has entered the
filter system, water is flowing over
(instead of through) the foam filters.
Control system is exposed to excessive
heat (sun, ambient temperature)
− Manual cleaning
Pump status detection incorrectly set
− Automatic mode
− Time-dependent
The filter pump is switched off.
cleaning
The impeller unit of the filter pump is
blocked.
Remedy
− Clean edge of the drum/drum seal and grease edge of
the drum Only use original OASE grease (order number
27872).
− Ensure that the rollers move smoothly
− Remove larger particles (e.g. snails, stones) from the
sprocket
Disassemble the drum and ensure that the drum seal is
positioned correctly during re-assembly
Align the container horizontally
Wait until the soiling decreases
− This operating status is atypical. Avoid long-term
operation in this state.
− Clean the pond
− Reduce the amount of soiling
− Install the filter pump in an elevated position.
Clean the screen elements, descale (→ Replacing screen
element)
− Clean nozzle
− Clean outlet pipes
− Enlarge outlet opening
− Reduce flow rate
− Clean foam filters
Protect the control system from heat
Set the pump status detection. (→ Setting the filter pump
status detection)
Switch on the filter pump.
Clean the filter pump.
Resetting the system
message
Press
key for 5 s
− Press
key for 5 s
− Automatic if the number
of cleaning procedures
drops below 960.
Automatic when cooled down
Automatic after elimination of
the cause