Connecting The Egc Box; Connecting An Additional Egc Compatible Unit; Installing The Control System With Egc Box; Pump Fed System - Oase ProfiClear Premium Compact EGC Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 130
4.3.2

Connecting the EGC box

Integration of the filter system into the EGC network is optional and not necessary for operation. (→ Easy
Garden Control System (EGC))
The Connection Cable EGC cable is required for connecting the EGC box.
The correct fastening of the plug connector is important for a secure connection and an interference-free
EGC network.
How to proceed:
 N, O
1. Remove the protection cap from the unit.
2. Fit the plug connector and secure with the two screws (max. 2.0 Nm).
– Ensure that the rubber seal is clean and fits exactly.
– Replace the rubber seal if damaged.
3. Remove the protection cap from EGC-OUT of the last unit in the EGC network, fit the terminal resistor
and secure it with the two screws (max. 2.0 Nm).
– No EGC Connection Cable is connected to EGC-OUT on the last unit in the EGC network. The
terminal resistor has to be fitted to this EGC-OUT so that the EGC network is correctly terminated.
– The terminal resistor is included in the delivery scope of the EGC-Master.
4.3.3

Connecting an additional EGC compatible unit

An additional EGC compatible unit can be connected to the EGC box.
► Ensure the correct connection.
How to proceed:
 N, O
1. Remove the protection cap from EGC-OUT on the EGC box and fit the plug connector of the
EGCConnection Cable.
2. Remove the protection cap from EGC-IN on the additional unit and fit the other plug connector of the
EGC Connection Cable.
3. Remove the protection cap from EGC-OUT on the additional unit and fit the terminal resistor or
connect an additional EGC unit.
4.4

Installing the control system with EGC box

4.4.1

Pump fed system

 L
► Install the control system at least 2 m away from the pond.
► Protect the control system from direct sunlight.
► The control system is splash-proof and may be exposed to rain.
► Suspended installation of the control system: Either on the mount on the container wall of the Drum
Filter Module or using the threaded hooks in another position.
4.4.2

Gravity fed system

 M
► Install the control system at a minimum distance of 2 m from the pond.
► Protect the control system from direct sun radiation.
► The control system is splash-proof and may be exposed to rain.
► Push both ground stakes onto the control system and push the ground stakes into the ground.