FUNCTIONAL TESTS
Checking
The FX24 checks the operating relays and safety mechanisms before running the opening and closing cycles.
If a malfunction occurs, make sure that the connected devices operate correctly and check the wiring.
During the opening and closing phases, the screen displays four digits separated by a decimal point, e.g. 35.40. The
digits are updated during motion and represent the maximum torque reached by motor 1 (value 35) and by motor 2
(value 40).
If the maximum torque value reached during motion is close to the set value, operating anomalies may appear due to
wear or to any slight deformation affecting the gate section.
CLEARING REMOTE CONTROLS AND ALL
SETTINGS
Clearing all remote controls
Press the controller's "PROG" button for more than seven seconds. The indicator blinks to show that all of the remote
controls are cleared.
Clearing all settings
[1] Press OK twice to access the menus.
[2] Use the + and – buttons to call up the preset
menu.
[3] Press OK to clear all of the settings.
The motor drive system is reset and reverts to its
initial confi guration.
Before using the motor drive system, perform
a new learning cycle.
Copyright © 2008 Somfy SAS. All rights reserved.