TROUBLESHOOTING

Meaning of the messages displayed on-screen

Before accessing the list of menus, the FX24 screen displays the following information:
Somfy
Product name
FX24 software version level
Number of cycles performed (a value expressed in hundreds). During the fi rst 100 operations, the screen displays 0000.
If incorrect operation occurs, a message is displayed showing which mechanism should be checked. If the problem found
cannot be corrected, contact Somfy technical support.
The screen located on the electronic circuit board displays useful information during normal operation and when faults
occur.
The following messages indicate which mechanism to check:
Message
Meaning
OK
Learning successful
KO
Learning failed
Awaiting a value or function
End
Exit programming mode
SuC
Closing limit stop enabled
SuO
Opening limit stop enabled
AMP
Obstacle detected
PED
Pedestrian entrance function on
START
START input on
STOP
STOP input on
PHOT
PHOT input on
CLOSE
CLOSE input on
OPEN
OPEN input on
SWO1
Motor 1 opening limit stop input on
SWC1
Motor 1 closing limit stop input on
SWO2
Motor 2 opening limit stop input on
SWC2
Motor 2 closing limit stop input on
TH
Software thermal protection function triggered

REMOVING THE CONTROLLER

Warning: This operation must be performed by qualifi ed personnel.
If the FX24 controller is to be removed and refi tted elsewhere:
cut the power supply and disconnect the entire electrical installation,
if some components cannot be removed or are damaged, replace them
14
Comments
Ensure that the peripheral that controls the pedestrian entrance is
operating properly.
Ensure that the peripheral that controls the START input is operating
properly.
Ensure that the peripheral that controls the STOP input is operating
properly.
Ensure that nothing is blocking out the photoelectric cells.
Ensure that the peripheral that controls the CLOSE input is operating
properly.
Ensure that the peripheral that controls the OPEN input is operating
properly.
Electro-magnetic detection system failure. Replace it.
Electro-magnetic detection system failure. Replace it.
Electro-magnetic detection system failure. Replace it.
Electro-magnetic detection system failure. Replace it.
Wait for this message to be cleared before continuing to use the motor
drive system.