RIB T2 Serie Importantes Instrucciones De Seguridad Para La Instalación página 23

Ocultar thumbs Ver también para T2 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

POINT B
- SETTINGS
DIP 1
(ON) MOTOR ROTATION DIRECTION CHECK (See Point C)
DIP 2
(ON) PROGRAMMING (See Point D)
DIP 1-2 STORAGE/DELETION OF RADIO CODES FOR COMPLETE OPENING
(DIP 1 ON followed by DIP 2 ON) (POINT G) ONLY FOR CRX MODELS
DIP 1-3 STORAGE/DELETION OF RADIO CODES FOR PEDESTRIAN OPENING (DIP 1 ON
followed by DIP 3 ON) (POINT H) ONLY FOR CRX MODELS
DIP 2-1 PROGRAMMING OF THE PEDESTRIAN OPENING (See Point F)
DIP 3
ON - Automatic Closing ENABLED
OFF - Automatic Closing DISABLED
DIP 4
ON - Photocells active only in closing
OFF - Photocells always active
DIP 5
ON - blinker pre-flashing
OFF - blinker normal-flashing
DIP 6
OFF - STEP BY STEP
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
Radio Receiver command
ON - AUTOMATIC
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
Radio Receiver command
DIP 7
ON - low speed in approaching ENABLED
OFF - low speed in approaching DISABLED
DIP 8
ON - electric lock command ENABLED
OFF - electric lock command DISABLED
DIP 9
ON - Hammering on complete close position to ease Manual Release
- Hammering before opening to ease electric lock unlocking
OFF - no impulse
DIP 10
ON - Extra thrust when reached closing position to make sure that the mechanical
bolt is fixed into the ground
OFF no impulse
DIP 11
ON - black out function ENABLED (See chart 2)
OFF - black out function DISABLED
DIP 12
ON - close command after the transit through the photocell ENABLED
OFF - close command after the transit through the photocell DISABLED
DIP 13
ON - safety strip self-test ENABLED
OFF - safety strip self-test DISABLED
DIP 14
to select type of motor (see chart 1)
DIP 15
to select type of motor (see chart 1)
DIP 16
to select type of motor (see chart 1)
JP 17 OPEN JUMPER 1 motor (M1) - 1 leaf
CLOSE JUMPER 2 motors (M1 and M2) - 2 leaves
JP1 => Pay attention that the jumper is inserted!
JP2 => Pay attention that the jumper is inserted!
JP3 => Pay attention that the jumper is inserted!
TORQUE TR1 Electronic regulator for motor torque
Adjustment of motor torque is carried out using the TORQUE Trimmer which varies the output
voltage to the head/s of the motor/s (turn clockwise to increase torque).
This torque control is activated after 2 seconds form any manoeuvre begging, whereas the
motor is turned on at full power to guarantee the starting at the manoeuvre begging.
PAY ATTENTION: IF THE TORQUE TRIMMER SETTING IS CHANGED, IT IS PREFERABLE
TO REPEAT THE TIME PROGRAMMING.
LOW SPEED TR2 Electronic regulator for low speed on approach
Adjustment of low speed is carried out using the LOW SPEED Trimmer which varies the output
voltage to the head/s of the motor/s (turn clockwise to increase speed). Adjustment is carried
out to establish the correct speed at the completion of opening and closing, depending on the
structure of the gate, or if there is any light friction that could compromise the correct working
of the system. The low speed is activated (DIP7 OFF) when the gate leaf is 0.50-0.60 meters
away from the complete close or open position.
ATTENTION: WHEN USING HYDRAULIC OPERATORS
When using the hydraulic operators the deceleration phase may not operate correctly;
in that case it is advisable to disable the feature of the deceleration by putting DIP 7
in the OFF mode.
LED WARNING
DL1 - programming activated (red)
DL2 - radio code programming (green) (only for CRX)
DL3 - gate opening M2 (green)
DL4 - gate closing M2 (red)
DL5 - gate opening M1 (green)
DL6 - gate closing M1 (red)
TYPE OF MOTOR
1
KING 230/50
KING L 230/50
KING 220/60
KING L 220/60
KING ICE 230/50
2
MAGIC IRR. 105°
MAGIC IRR. 180°
MAGIC REV. 105°
MAGIC REV. 180°
DUKE 110°
DUKE 180°
PRATIC
3
PRINCE REV
4
IDRO DUE 27/R
IDRO DUE 27/1B
IDRO DUE 27 SUPER/R
IDRO DUE 27 SUPER/1B
5
FLUID R DVI
FLUID R SVI
FLUID 2B DVI
FLUID 2B SVI
IDRO 39/R
IDRO 39/1B
IDRO 39/2B
6
KING FAST 230/50
KING 120/60
KING L 120/60
7
R50
8
IDRO C 27/1B
IDRO C 27/2B
IDRO C 27/R
DL7 - photocell contact (NC) (red)
DL8 - safety strip contact (NC) (red)
FUSES
F1 T315mA
Accessories protection fuse
F2 5A
Motor protection fuse
POINT C
- MOTOR ROTATION DIRECTION CHECK
1 - Unlock the operators with the Manual Release - swing open the leaves about halfway and
lock again the operators.
2 - Turn DIP1 to ON position The red LED DL1 starts blinking.
3 - Press the PROG button and hold it - When GREEN LEDS DL3 and DL5 are on, the gate
leaves are opening (with a phase shift of 2 seconds). Check the leaves swinging and
the opening mechanical stopper position (movement is now performed in "man present"
mode, open-close-open-etc.).
If any of the leaf closes instead of opening, release PROG button, turn off the main power
and reverse the two phase wires (V1/2 and W1/2) of the relevant motor/s.
4 - Press the PROG button and hold it to CLOSE completely the gate. When RED LEDS DL4
and DL6 are on, the gate leaves are closing (with a phase shift of 4 seconds). Check
leaves swinging and the closing mechanical stopper position.
5 - After 3 seconds motor starting and for the next 10 seconds motor working, the torque
controls automatically activated. Set the motor torque by the TORQUE Trimmer/s which
varies the output voltage to the motor/s (turn clockwise to increase the torque).
6 - After other 10 seconds motor working, the low speed controls automatically activated
(DIP7 ON). Set the motor low speed by the LOW SPEED Trimmer to select the gate leaf
low speed in approaching.
7 - Close completely the gate.
8 - Turn DIP1 to OFF position, LED DL1 turns off.
During Point C procedure, safety devices (photocells and safetystrip) are not active
and the remote control cannot operate.
(#) In Point D, Point E and Point F procedures, all the safety devices (photocells and safety
strip) will be active, so they must be properly installed and connected to the control board.
Any changing of the safety devices input state, will stop the Point D, Point E or Point F
procedure that must be repeated from the beginning.
POINT D
- PROGRAMMING FOR 2 MOTORS (#)
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, LED DL1 starts blinking
23
23
TABLE 1
CODE
DIP 14
DIP 15
AA14001
OFF
OFF
AA14010
AA14002
AA14011
AA14019
AA10960
ON
OFF
AA10965
AA10920
AA10930
AA10975
AA10985
AA18001
AA14045
OFF
ON
AA10843
ON
ON
AA10844
AA10809
AA10804
AA10899
OFF
OFF
AA10901
AA10897
AA10898
AA10871
AA10876
AA10881
AA14008
ON
OFF
AA14003
AA14012
AA21580
OFF
ON
AA10884
ON
ON
AA10882
AA10883
G
B
DIP 16
OFF
OFF
OFF
OFF
ON
ON
ON
ON

Publicidad

Tabla de contenido
loading

Tabla de contenido