SmartWasher
Troubleshooting
If you are having a problem with your SmartWasher not functioning properly, check the
following troubleshooting LED's through the control box on the side of the base:
No Flow
If the machine is getting power and heating but not pumping,
the PUMP LED will be either solid on, blinking, or off.
• If the PUMP LED is On with pump switch up and there is no flow, the pump is malfunc-
tioning and must be replaced.
• If PUMP LED is blinking, flip pump switch down and back up to reset.
• If PUMP LED is Off with pump switch up, please call ChemFree Technical support for
further assistance.
No Heat
(be aware fluid level must be above 8 inches [20 cm] to heat)
Are the Add Fluid lights on?
YES - Add Fluid lights are on
• Lift float on probe to up position and see if FLUID LED goes off. If not, probe is mal-
functioning and needs to be replaced. If FLUID LED does go off, there is not sufficent
fluid in base (8" to 10") (20 cm to 25 cm).
NO - Add Fluid lights are not on - CHECK FLUID & HEATER LED's
• If FLUID LED is off and the HEATER LED is on, heater will need to be replaced.
• If FLUID LED is off and the HEATER LED is off, the probe's thermistor is bad and the
probe will need to be replaced.
No Power
Check to see if there are any blinking LED's inside the control box. It is possible the
machine is still heating and just not pumping. If that is the case, see No Flow. If the
POWER LED is not blinking, check to see if the power circuit has tripped or there may
be no power from that outlet. If the outlet is providing power and the unit will still not
power on, contact ChemFree Technical Support for further assistance.
ChemFree Technical Support 1-800-521-7182 x2624
www.ChemFree.com
5