Air-to-water Heat Pump
to malfunction, enter the corresponding emergency mode; as to heating mode, after entering the emergency mode,
heating can only be realized through e-heater of the indoor unit. When the setting outflow temperature or indoor
temperature is reached, the e-heater of indoor unit will stop running; as to water heating mode, the e-heater of
indoor unit stops while the e-heater of water tank runs. When the setting temperature or water tank is reached, the
e-heater will stop running.
Quick water heating: in quick water heating mode, the unit runs according to the water heating control of heat
pump and the e-heater of water tank runs at the same time.
Forced Operation Mode: this mode is only used for refrigerant recovery and debugging for the unit.
Holiday mode: this mode is only available for heating mode. This mode is set to keep indoor temperature or
leaving water temperature in a certain range, so as to prevent water system of the unit from freezing or protect
certain indoor articles from freezing damage. When the outdoor unit stops due to malfunction, the two e-heaters of
the unit will run.
Disinfection mode: in this mode, the water heating system can be disinfected. When starting up the disinfection
function and setting corresponding time to meet the requirement of disinfection mode, the function will start. After
the setting temperature is reached, this mode will terminate.
Weather-dependent Operation: this mode is only available for space heating or space cooling. In Weather-
dependent mode, the setting value (remote room air temperature or leaving water temperature) is detected and
controlled automatically when the outdoor air temperature is changed.
Quiet mode: Silent mode is available in cooling, heating and water heating mode. In silent mode, the outdoor
unit will reduce the running noise via automatic control.
Floor commissioning: this function is intended to preheat the floor periodically for the initial use.
Air removal of the water system: this function is intended to replenish water and remove air in the water
system to make the equipment run at the stabilized water pressure.
Solar water heater: when the condition for starting the solar water heater is satisfied, the solar heater will start
to heat the circulation water. Then the heated water will go to the water tank and exchange heat with water in it. At
any condition, the solar water heater will be given priority for startup so as for energy conservation.
Other thermal: when the outdoor temperature is lower than the set point for starting other thermal and the unit
is under the error condition and the compressor has stopped for three minutes, then the other thermal will start to
supply heat or hot water to the room.
3. Nomenclature
G
RS
-
1
2
NO.
Description
1
GREE
2
Heat Pump Water Heater
3
Heating Mode
4
Function
5
Nominal Heating Capacity
6
Compressor Style
7
Refrigerant
8
Design Serial Number
9
Power Supply
10
Indoor and Outdoor Unit Code
C
Q
16
3
4
5
G-GREE Air to water heat pump
RS
S= Static; C=Circulating
Q=Multi-function; Omit=Single-function
6.0=6.0kW; 8.0=8.0kW;10=10kW; 12=12kW; 14=14kW; 16=16kW
Pd=DC Inverter; Omit=On/Off
Na=R410A
B,C,D......
K=220-240V,~,50Hz;M=380-415V,3N~,50Hz;H=380V,3N~,60Hz
I=Indoor unit; O=Outdoor unit
12
Pd
/
Nh
6
7
Options
MONOBLOC TYPE
G
-
M
8
9