MONOBLOC TYPE
NO
CN8
Notes
(a) Distance between the indoor unit and the remote air temperature sensor should be less than 15m due to
length of the connection cable of remote air temperature sensor;
(b) Height from floor is approximately 1.5m;
(c) Remote air temperature sensor cannot be located where the area may be hidden when door is open;
(d) Remote air temperature sensor cannot be located where external thermal influence may be applied;
(e) Remote air temperature sensor should be installed where space heating is mainly applied;
(f) After the remote air temperature sensor is installed, it should be set to "With" through the wired controller so
as to set the remote air temperature to the control point.
9. Thermostat
Installation of the thermostat is very similar to that of the remote air temperature sensor.
Remote Air Temperature Sensor
NO
PCB
Electric box
Versati III
XT4
23
24
25
26
Thermostat
1
2
3
4
YES
1.5 Meters
Remote Air Environmen t
Temp sensor
15K
CN1
AP
2
25
Air-to-water Heat Pump
NO
NO
Doors
RT6