KP 2203
Phase digital power clamp meter
Saving Measurement
In measurement mode, you can press
button to save the present
SAVE
display to a memory location.
The meter can store 28 groups of
measurement date.
When the meter has saved 28 groups
of date, you press
SAVE
to save again, the display shows
"FUL" symbol to prompt full
memory in the meter now. You must
press
button to clear the
CLEAR
memory and continue saving new
date.
Recalling Memory
If something is saved in the meter
memory, use following procedure
to display of a memory location:
1.
Turn the selector to MR.
2.
The display shows "MR" and
"HOLD" symbol, location
number and date in current
memory location.
3.
Press
button and
MAX
button to cycle through memory
location.
RS232C Data Interface
Connect RS232C interface cable to
the clamp meter as shown in Figure
18, then rotate the interface cable
deasil to lock it in the meter. Connect
the other plug of the interface cable
Instructions manual |
54
to a serial port of a computer. Then
the meter can transmit measured
data to computer by the infrared
photoelectricity RS232C interface
in real-time mode. If you want to
take out the interface cable from the
meter, first you must rotate the cable
widdershins to unlock it, then you
can pull out it .
button
You will install the special data
record software into the computer
according to README.TEXT file in
SETUP disk. When the meter is in
measurement mode, press
button, you can record and print the
measured data of the meter in real
time mode in the WINDOWS. The
software can record, plot, print data
and curve.
Input Voltage And Current
When the meter is in power
measurement mode, if input voltage
exceeds 600V(TRMS)or current
exceeds 1000A (TRMS), the meter
will display "OL" symbol, and bar
MIN
graph is full. When input voltage
exceeds 30V, the
in the display for safety.
Backlight Display
When press
of LCD display is on. After lighting for
4 seconds the backlight is self-off.
RS232
symbol is shown
button, backlight