Página 1
Adam Equipment MDW – 300L HEALTH AND FITNESS SCALE with BMI Serie MDW-300L BÁSCULA DE SALUD Y GIMNASIA CON IMC Software EMW-250L-20080601 p.n. 700660159 Rev. A2, Apr 2014 ADAM EQUIPMENT CO. LTD. p.n. 700660159 Rev. A2, Apr 2014 Page 1...
CONTENTS INTRODUCTION ................... 3 TECHNICAL SPECIFICATIONS ..............3 DISPLAY AND KEY DESCRIPTIONS ............4 SETTING UP THE SCALE ................5 FUNCTION ....................7 WEIGHING ....................7 MEASURING HEIGHT ................8 MEASURING BODY MASS INDEX (BMI) ..........8 CALIBRATION ....................9 USER PARAMETERS ................
1.0 INTRODUCTION • The MDW 300L scale is a Digital Health and Fitness Scale with Body Mass Index (BMI) readout. • It is an accurate electronic device with advanced design and stable performance. • It is designed to measure both the weight and the height of a person and compute the BMI index.
3.0 DISPLAY AND KEY DESCRIPTIONS KEYS FUNCTIONS [On/Off / To turn the scale on or off. Zero] To zero the scale if the display drifts from zero. [Tare] ↵ To tare the scale, if necessary. Accept settings as required [Units / To toggle the weighing unit between Kg and Lb.
4.0 SETTING UP THE SCALE • Take the scale out of the box. 1. Locate the 4 screws (2) 2. Place the cable (4) through the pillar (3). 3. Insert the 4 screws (2) through the holes on the pillar bracket and secure the bracket to the indicator (1), 4.
Página 6
9. Place the indicator cable (4) and the load cell cable (13) together near the hole on the base (16). 10. Plug the two connectors (15) together. 11. Position the connector inside the base (16). 12. The cables should be fixed to the base using the clip provided (14).
5.0 FUNCTION WEIGHING • Place the Scale on an even floor and press the [On/Off] key. • The instrument performs a self-test after which it is ready for operation. • Press the [On/Off] key and the machine switches off. • The person to be weighed can step on to the platform once the scale shows 0.0 on the display.
MEASURING HEIGHT • To measure someones height, it is necessary to extract the measuring rod and place the height arm on top of the head of the person being measured. • For shorter heights the height arm can be released by pressing the red button on the top of the height rod, and then moving the height arm to the lower section of the height pillar.
6.0 CALIBRATION Before calibrating the scale, you should ensure that you have a suitable known weight for calibration. 1. When in normal weighing mode with the scale at zero press and hold down [TARE] and [ON / OFF] keys to enter the calibration mode. 2.
7.0 USER PARAMETERS This indicator has 4 parameter settings that can be selected. When the scale is in normal weighing mode, press and hold down the [ON / OFF] key and the [UNIT] key for 3 seconds until ‘Setup’ is shown on the display. When in the SETUP mode, press the [Print/Hold] key to change the flashing digits, and [TARE] key to confirm the flashing digits and move to the next parameter setting.
8.3 When Parameter S.F. in section 7 is set to 1 : Continuous output of the current displayed reading and unit, and no data is received. The output format is as below: <LF>< reading, minus, decimal point, weight unit>GR<CR><EXT> Or <LF>< reading, minus, decimal point, weight unit>NT<CR><EXT> 8.4 When Parameter S.F.
Página 13
U1U2: measure units, kg, lb 8.5.3 Commands and response (1) Command: W<CR> (57h 0dh) Response: ①<LF> ^^^^^^u1u2<CR ><LF>H1H2H3<CR ><E TX>---over capacity ②<LF>_ _ _ _ _ _ u1u2<CR><LF> H1H2H3 <CR ><E TX>---under capacity ③<LF>---------u1u2<CR><LF> H1H2H3<CR><ETX>---zero-point error ④< L F > < p > w 1 w 2 w 3 w 4 w 5 w 6 < d p > w 7 u 1 u 2 < C R > < L F > H 1 H 2 H 3 < C R > <ETX>...
Página 14
Table1: The status bit s definition: Byte 1 (H Byte 2 (H Byte 3 (H 0= not under 0= stable capacity 01= normal w ork 1= under mode 1= not stable capacity 10= hold w ork mode 0= not at zero 0= not over 00= not define point...
9.0 ERROR MESSAGES 0ˉ ˉ ˉ ˉ ˉ Zero point is over the setting range 0_ _ _ _ _ Zero is below the setting range Adˉ ˉ ˉˉ ADC is over max. range; Ad _ _ _ _ ADC is below min. range; There is an error in the EEPROM EEP.Er There is an error in calibration...
WARRANTY INFORMATION Adam Equipment offers Limited Warranty (Parts and Labour) for the components which fail due to defects in materials or workmanship. Warranty starts from the date of delivery. During the warranty period, should any repairs be necessary, the purchaser must inform their supplier, or Adam Equipment Company.
Página 33
ADAM EQUIPMENT è un' azienda con certificazione ISO 9001:2008 globale con più di 40 anni di esperienza nella produzione e vendita di apparecchiature elettroniche. I prodotti sono venduti attraverso una rete di distribuzione mondiale sopportati da aziende ADAM in UK (Ufficio Centrale), Germania,USA, Sud AFRICA, Australia e Cina .
Página 35
State of California to cause cancer and birth defects or other reproductive harm. Adam Equipment products have been tested with, and are always supplied with mains power adaptors which meet all legal requirements for the intended country or region of operation, including electrical safety, interference and energy efficiency.