To switch off, proceed in reverse order.
TO TEST THE RCD
O = Test button: the switch must break the circuit
(machine switches off).
WARNING:
• If in the test mode the switch does
not break the circuit, we recommend
that the unit is inspected by an
authorized D
WALT repair agent.
E
• It is not permitted to make any
modifications to the machine, in
particular it is not allowed to open
the PRCD or to repair or replace the
cable.
• Never use the PRCD as a main
switch. Always switch the PRCD
under no load condition.
ASSEMBLY AND ADJUSTMENTS
WARNING: To reduce the risk of
injury, turn unit off and disconnect
machine from power source before
installing and removing accessories,
before adjusting or changing set-
ups or when making repairs. Be sure
the trigger switch is in the OFF position.
An accidental start-up can cause injury.
Fitting the Side Handle (fi g. 3)
The side handle (e) can be fitted to suit both
RH- and LH-users.
WARNING: Always use the tool with
the side handle properly assembled.
1. Twist the side handle to loosen it.
2. For RH-users, slide the side handle clamp over
the collar, handle at the left.
For LH-users, slide the side handle clamp over
the collar, handle at the right.
3. Rotate the side handle to the desired position
and tighten the handle.
Mounting and Removing an
Accessory (fi g. 4)
This tool uses threaded core bits and adaptors
which thread directly onto the spindle (d).
We recommend to use professional accessories
only.
1. Choose the appropriate core bit for wet or dry
drilling.
2. Follow the core bit or manufacturer's
recommendations for mounting the accessory.
You may require an adaptor to fit the bit onto
the spindle.
3. Hold the spindle using the open-ended wrench (r)
and tighten the core bit (s) by rotating clockwise
using the open-ended wrench (t).
WARNING: Make sure the entire
assembly is tight before starting the
operation.
Two Gear Selector (fi g. 1)
The tool is fitted with a two gear selector (f) to vary
the speed/torque ratio.
1. Release the switch and select the required
position after the motor has come to a
complete standstill.
2. Always align the selector with the marks on the
gear housing.
3. Refer to the technical data to choose the
appropriate gear according to the diameter of
the core bit and the material to be drilled.
4. Do not change gears at full speed or during use.
Connecting to a Water Supply (fi g. 5)
D21582
These tools have a standard 1/8" pipe thread for the
water supply fitting (g).
1. Remove the cap screw (u). Store the cap screw
in a safe place.
2. Screw the male end of the water hose (v) into
the fitting (g) and tighten firmly.
3. Close the water tap (w).
4. Connect the water hose to an appropriate water
supply system.
WARNING: Make sure that the
pressure of the water supply is below
the max. pressure as stated in the
technical data.
Regulating the Water Flow (fi g. 5)
The water tap (w) on the water hose can be
adjusted to regulate the flow of cooling water
towards the drill bit.
1. To reduce the flow, turn the tap clockwise.
2. To increase the flow, turn the tap
counterclockwise.
Prior to Operation
1. Mount the appropriate accessory.
EN GLIS H
39