11 Backup mode
11.1 Mains power failure
After 5 minutes of power failure, TYDOM 2.0 sends a notification to the alarm
control unit. The alarm control unit beeps.
TYDOM 2.0 sends you a notification of the power defect and continues sending
alarms via the GSM connection for 24 hours. It is no longer controllable remotely.
After the 24 hour period, TYDOM 2.0 switches to energy saving mode, no other
function is available.
As soon as the mains power supply is restored, an end of defect notification is
sent to the alarm control unit.
The battery is designed to backup 22 power failures for 10 years.
Power
failure
5 mn
TYDOM 2.0
beeps
every 10 seconds
During a power failure, the video transfer function is not available.
The transfer of video links will resume when the power and Internet access are restored.
11.2 Internet connection down.
After 5 minutes without Internet access,
TYDOM 2.0 sends a notification to the alarm control unit.
TYDOM 2.0 continues to send the alerts via the GSM connection, but cannot
be controlled by the application. The transfer of video links will resume when the
mains power is restored.
You can activate or deactivate the alarm by using the menus proposed by the
speech synthesis system of TYDOM 2.0.
- Dial the installation's call number and let TYDOM 2.0 speech synthesis guide
you.
As soon as the Internet connection is restored, an end of defect notification is
sent to the alarm control unit.
Defects or end of defect detections are stored and can be viewed with the
CLT 8000 TYXAL+ touch screen keypad:
Menu - Info - History logs.
TYDOM 2.0 permanently checks the telephone line and IP connection. In the
event of a defect, this symbol
Enter your access code to discover the details of the defects.
Backup mode
alert transmission
comes up on the touch screen keypad.
60
24 h
Switches to
energy saving mode
ADSL BOX
IP
25/11/15
25/11/15
12:48
12:48
OFF
OFF
My house
My house
Info
Info
Settings
Settings